Gree 13-04686 Manuel d'utilisation - Page 19
Parcourez en ligne ou téléchargez le pdf Manuel d'utilisation pour {nom_de_la_catégorie} Gree 13-04686. Gree 13-04686 20 pages.
Avoid Service Checklist
INSTALLER L'APPAREIL INTERNE
OCCURRENCE
Air conditioner turns on and off
rapidly.
Noise when unit is cooling.
Water dripping INSIDE when unit is
cooling.
Water dripping OUTSIDE when unit
is cooling.
Remote Sensing Deactivating
Prematurely (Some Models).
Room Too Cold.
SOLUTION
Doors, windows, registers, etc. open - cold air escapes.
Close doors, windows, registers, etc.
Unit recently turned on in hot room. Allow additional time
to remove "stored heat" from walls, ceiling, floor and
furniture.
Dirty air filter - air restricted. Clean air filter.
Outside temperature extremely hot. Set FAN speed to a
faster setting to bring air past cooling coils more frequently.
Air movement sound. This is normal. If too loud, set to a
slower FAN setting.
Window vibration - poor installation. Refer to installation
instructions or check with installer.
Improper installation. Tilt air conditioner slightly to the out-
side to allow water drainage. Refer to installation instruc-
tions - check with installer.
Unit removing large quantity of moisture from humid
room. This is normal during excessively humid days.
Remote control not located within range. Place remote
control within 20 feet & 180°, radius of the front of the
unit.
Remote control signal obstructed. Remove obstruction.
Set temperature too low. Increase set temperature.
19