HIDfast HIDfast Series Manuel d'installation - Page 4
Parcourez en ligne ou téléchargez le pdf Manuel d'installation pour {nom_de_la_catégorie} HIDfast HIDfast Series. HIDfast HIDfast Series 4 pages. Pneumatic decking system
Quick reference for psi settings needed in different material,
in some cases more or less may be required.
Cedar
Mahogany
Redwood
PVC
Cypress
(70 to 90)
Fir
(50 to 70)
Trouble shooting,
1
Fastener not driven in
raise the psi,
Fastener is set to deep,
lower psi
Fastener is to high,
adjust the foot plate up, or joist attachment down.
Fastener to low,
adjust the foot plate down, or joist attachment up.
Decking not flat,
not standing on, or not driving decking on properly,
see instructions, and website.
Fastener dose not fire,
check magazine for blockage, check clips for flatness, dose
pusher have spring pressure, can't find problem call for service
Composite
Ipe-grooved only
Grooved only
(80 to 100)
(70 to 100)
2
decking is too hard, use grooved decking
.
7