Dynamic Polarized-Media Instructions d'installation - Page 2
Parcourez en ligne ou téléchargez le pdf Instructions d'installation pour {nom_de_la_catégorie} Dynamic Polarized-Media. Dynamic Polarized-Media 4 pages. Polarized-media electronic air cleaner
If a Common or 24vac terminal cannot be located, it will be necessary to install a separate
transformer. If a hard-wired transformer is used, an isolated class II transformer is recommended.
The transformer must be installed according to local codes and ordinances.
5) If necessary, route the power cord through the furnace/air handler cabinet to the filter rack
area. If an existing access hole is not available, drill a 7/16" hole. A grommet is provided to fit a
7/16" hole (fig 2). The cord should be run so that it is not crimped or abraded and should have
enough slack to allow the air cleaner to be easily removed for routine maintenance. Position the
power cord slack to keep it away from the furnace/air handler blower and other moving parts.
6) Install the air cleaner into the filter rack or return air grille.
7) Plug the power cord into the air cleaner once it is securely in place (fig 3).
8) Close the filter access door or grille.
9) Turn on the power to the furnace/air handler. The power indicator light on the air cleaner
should illuminate.
10) Turn the thermostat fan switch to the "ON" position.
Figure 3
11) If arcing occurs within the air cleaner, see the instructions in section III for replacing the air
cleaner Media Pad.
12) Affix the caution sticker and Media Pad Replacement Record in a prominent location near the
air cleaner.
Section II. Optional Plug-In Transformer
As an optional accessory, a plug-in transformer (part no. A412402) is available to plug into any
110-Volt (AC) outlet to provide 24-Volt (AC) power to the unit.
WARNING: DO NOT SUBSTITUTE OTHER 110VAC–24VAC TRANSFORMERS AS DAMAGE
COULD RESULT TO THE UNIT ELECTRONICS AND VOID THE AIR CLEANER WARRANTY.
Section III. Maintenance and Media Pad Replacement
Replacement Media Pads are available from your heating and air conditioning contractor or by
ordering online at www.DynamicAQS.com
WARNING:
WHENEVER INSTALLING OR REMOVING THE AIR CLEANER, THE
POWER TO THE FURNACE/AIR HANDLER MUST BE TURNED OFF. CARE SHOULD
BE TAKEN NOT TO LET THE JACK TOUCH ANY GROUNDED OR METAL SURFACES.
ALTHOUGH THE JACK IS SHIELDED, IT IS POSSIBLE FOR THE CENTRAL POWER
INSERT TO CONTACT GROUND WHICH COULD RESULT IN DAMAGE TO THE
TRANSFORMER OR ELECTRONICS.
Figure 2
NOTE: For best air cleaning efficiency and
optimum comfort, the furnace/air handler
blower should be run continuously with the
fan switch in the "ON" position rather than in
the "AUTO" position.
.
2