6.1. PROCEDURE FOR REPLACING CARTRIDGES AND THE MEMBRANE
a. Close the water supply brass ball valve (figure 5).
b. Open the faucet (figure 2) to relieve the pressure from inside the osmosis sys-
tem.
c. To change any of the cartridges and/or membrane they must be turned clock-
wise and pulled downwards to remove it from its cap as indicated in the follow-
ing figure. This process must be carried out for each of the cartridges that you
want to replace.
d. Remove the cartridges/membrane from their original packaging. Each cartridge
and/or membrane must be placed in the corresponding position maintaining
the correct order. To do so, you must insert each cartridge in its cap and turn it
anti-clockwise. This process must be carried out for each of the cartridges that
you want to replace.
9