Celestron CGE1400 Manuel du protocole de communication - Page 3
Parcourez en ligne ou téléchargez le pdf Manuel du protocole de communication pour {nom_de_la_catégorie} Celestron CGE1400. Celestron CGE1400 8 pages. Schmidt-cassegrain optical tube assembly
Également pour Celestron CGE1400 : Manuel complémentaire (17 pages), Manuel d'instruction (12 pages)
Command Function
Variable rate Azm (or
RA) slew in positive
direction
Variable rate Azm (or
RA) slew in negative
direction
Variable rate Alt (or
Dec) slew in positive
direction
Variable rate Alt (or
Dec) slew in negative
direction
Fixed rate Azm (or RA)
slew in positive
direction
Fixed rate Azm (or RA)
slew in negative
direction
Fixed rate Alt (or DEC)
PC Command
"P" &
chr(3) &
chr(16) &
chr(6) &
chr(trackRateHigh) &
chr(trackRateLow) &
chr(0) &
chr(0)
"P" &
chr(3) &
chr(16) &
chr(7) &
chr(trackRateHigh) &
chr(trackRateLow) &
chr(0) &
chr(0)
"P" &
chr(3) &
chr(17) &
chr(6) &
chr(trackRateHigh) &
chr(trackRateLow) &
chr(0) &
chr(0)
"P" &
chr(3) &
chr(17) &
chr(7) &
chr(trackRateHigh) &
chr(trackRateLow) &
chr(0) &
chr(0)
"P" &
chr(2) &
chr(16) &
chr(36) &
chr(rate) &
chr(0) &
chr(0) &
chr(0)
"P" &
chr(2) &
chr(16) &
chr(37) &
chr(rate) &
chr(0) &
chr(0) &
chr(0)
"P" &
Hand Control
Applies to
Response
Versions
"#"
1.6+
"#"
1.6+
"#"
1.6+
"#"
1.6+
"#"
1.6+
"#"
1.6+
"#"
1.6+