Celestron CGE1400 Manuel du protocole de communication
Command Function
Variable rate Azm (or
RA) slew in positive
direction
Variable rate Azm (or
RA) slew in negative
direction
Variable rate Alt (or
Dec) slew in positive
direction
Variable rate Alt (or
Dec) slew in negative
direction
Fixed rate Azm (or RA)
slew in positive
direction
Fixed rate Azm (or RA)
slew in negative
direction
Fixed rate Alt (or DEC)
PC Command
"P" &
chr(3) &
chr(16) &
chr(6) &
chr(trackRateHigh) &
chr(trackRateLow) &
chr(0) &
chr(0)
"P" &
chr(3) &
chr(16) &
chr(7) &
chr(trackRateHigh) &
chr(trackRateLow) &
chr(0) &
chr(0)
"P" &
chr(3) &
chr(17) &
chr(6) &
chr(trackRateHigh) &
chr(trackRateLow) &
chr(0) &
chr(0)
"P" &
chr(3) &
chr(17) &
chr(7) &
chr(trackRateHigh) &
chr(trackRateLow) &
chr(0) &
chr(0)
"P" &
chr(2) &
chr(16) &
chr(36) &
chr(rate) &
chr(0) &
chr(0) &
chr(0)
"P" &
chr(2) &
chr(16) &
chr(37) &
chr(rate) &
chr(0) &
chr(0) &
chr(0)
"P" &
Hand Control
Applies to
Response
Versions
"#"
1.6+
"#"
1.6+
"#"
1.6+
"#"
1.6+
"#"
1.6+
"#"
1.6+
"#"
1.6+