Aire Sky Parlor Manuel d'instruction - Page 13

Parcourez en ligne ou téléchargez le pdf Manuel d'instruction pour {nom_de_la_catégorie} Aire Sky Parlor. Aire Sky Parlor 17 pages.

Aire Sky Parlor Manuel d'instruction

OPERATING THE REMOTE CONTROL

Remote Control only: Install an A23 12 volt battery (included). To prevent damage to transmitter remove the battery
if not used for long periods of time.
IMPORTANT: THIS REMOTE CONTROL & DC FAN MOTOR ARE DESIGNED TO PERFORM A ONE TIME SELF CALIBRATION
TEST. THIS TEST WILL BEGIN ONCE A NEW CODE HAS BEEN SET, AND WILL LAST APPROXIMATELY SIX MINUTES.
Your DC brushless motor is equipped with a self learning frequency function remote control. Restore power to ceiling fan
and test the transmitter as below for proper operation: ( figure 19)
A. 1, 2, 3, 4, 5 and 6 button:
These six buttons are used to set the fan speed as follows:
1 = minimum speed
2 = low speed
3 = medium low speed
4 = medium speed
5 = medium high speed
6 = high speed
B.
Reverse button:
This button is used to change the direction of the rotation of the blades;
forward for warm weather or reverse for warm weather.
C.
button:
This button turns the power Off to the Fan.
D.
Button:
fans that feature an UP light ( button) and a DOWN light ( button) that are controlled independent of each other; Press
and release the button for the desired light to turn the light ON or OFF. Press and hold the button to set the desired light
brightness. The light will cycle between bright and dim settings as long as the button is pressed. The light key has an
automatic auto-resume feature that allows the light to remain at the same brightness as the last time it was turned off.
Note: The auto learning function will only mandate within 60 seconds when turning the fan's AC power ON.
1. Select desired frequency from the back of transmitter.
2. Press the transmitter's "SET" button, and hold the "SET" button for over 5 seconds. Once the receiver has detected
the frequency, the fan will automatically begin to operate and start to rotate in the counter-clockwise direction and on
the highest RPM for 3 minutes. When counter-clockwise rotation has finished, the fan will automatically reverse to
clockwise direction again to the highest RPM for 3 minutes. Fan will shut off when the self calibration test has finished.
The total self calibration test will last about 6 minutes.
Note: During self calibration test, the remote will be non-function.
Note: The learning frequency function and self calibration test will continue to retain the last set frequency and
calibration set even when the AC power is shut off. If the frequency is changed the self calibration test will occur again.
1. Lock position: The DC motor has a built-in safety against obstruction during operation. The motor will get locked
operation and disconnect power after 30 seconds if interruption occurs. Please remove obstacles before re-set.
2. Over 80W protection: When the receiver detects motor power consumption which is greater than 80W, the receiver's
power will stop and operation will be immediately discontinued. Turn the receiver power on after 5 seconds.
3. "D" and "ON" dip switch:
The "D" selection is the light dimmable selection and is to be used with all bulbs except for CFL bulbs. The "ON" selection
is For CFL bulbs.
FIG. 19
13
3
4
5
2
1
6