Dynamix RC 907 EV 35 Manuel de l'utilisateur - Page 16

Parcourez en ligne ou téléchargez le pdf Manuel de l'utilisateur pour {nom_de_la_catégorie} Dynamix RC 907 EV 35. Dynamix RC 907 EV 35 16 pages. Ethernet to v.35 interface converter

2. There is some problem with connection between twisted pair and RJ-45
connector.
3. If there are bit errors in V.35 link, please check equipment alarm function,
or test bit error rate of V.35 link by bit error tester.
4. If the traffic through converter increases suddenly, it may cause congestion
within a short time, and result in disconnection of the network. In this case,
the network service with huge amount of traffic should be paused and
restarted after 10 seconds, and the network will be back to normal
condition. However, if a long time disconnection occurs, it is abnormal.
Please check the operation condition of equipments.
To improve the network efficiency, both the Ethernet equipment and the interface
converter shall be set in full duplex mode, with great attention to the matching of
working modes. RC907/908-EV35 may not be suitable for some IP-based image
transmission equipments.
Since the bit rate of pinging large-size packets may exceed transmission capability
of V.35 link, many packet losses may occur. To solve this problem, please try to
increase the timeout parameter of the 'Ping' command.
Network management software can only review, but not conduct
configuration
Answer: The possible reason is that some bits of the dip-switch are not set on the
default status. Please refer to Chapter 4 for details.
RC907/908-EV35 User Guide