11 Breakdown Maintenance
NO.
Malfunction
Temperature
1
Sensor CTN
heating wire
temperature
sensor
2
open-circuit
or
short-circuit
heating wire
3
assembly
4
door open
6
condenser
、
fault
indicator
Possible Cause
light
1、 whether the sensor is
malfunctioning?
E1
2、 Is the plug plugged in
firmly?
3、 Is it short-circuit?
1、 Is
the
temperature
malfunctioning?
E3
2 、 Whether the plug is
plugged in firmly?
3、Is it short-circuit?
4、 1、Is the plug plugged in
firmly?
E2
2、Whether the heating wire
is malfunctioned?
5、 1、Is the plug plugged in
firmly?
dop
2、 Whether the Micro-switch
is malfunctioned?
1、 Is
installed
enough?
E6
2、 Is
malfunctioned?
3、 Is the plug contact poor?
17
heating
wire
sensor
the
condenser
not
good
the
Micro-switch
Solution
1、replace the sensor
2、re-plug in
3、replace the wire
1、re-plug in
2、replace the wire
3、replace the heating wire
1、re-plug in the plug
2、replace the heating wire
1、 replace the Micro-switch
2、re-plug in the plug
1、 Re-install condenser in
the right way.
2、 replace
Micro-switch
the