Connection Examples 1
■ Advanced unit-Safety light curtain
Connections
Safety controller: Advanced unit SFC-A Series
Safety light curtain: SFL / SFLA Series
Contactor of rated load (from Annex C of ISO 13849-1)
SW1
SFL(A) Series
Emitter
SFL(A) Series
Receiver
MC4
MC3
MC2
SW1: Safety light curtain
MC1 to MC4: Contactor
M1, M2: 3-phase motor
• Operation timing chart
Safety light
curtain SW1
MC1, MC2 b contact
MC3, MC4 b contact
MC1, MC2 a contact
MC3, MC4 a contact
Motor controller
control signal
Rotation of M2 motor
• For more information on wiring and detailed settings for safety light curtain (SFL/SFLA Series), refer to the "
• The control output of the safety light curtain (SFL(A) series) is based on the PNP output.
• When you do not use the logic input (M61, M62), set the switch of the logic (AND) input (SW1, SW2) to OFF.
• Set the switches for off-delay time on the front and back of the advanced unit to the same.
Start
Auto
24VDC
FUSE
A1
A2
GND
NC
M11
Safety Input 1
M12
OSSD1
NC
M21
Safety Input 2
OSSD2
M22
M51
M52
M53
MC1
NC
M61
NC
M62
Safety controller: Advanced unit
Off-delay
time
PL/Safety category
PLe/Cat.4 equivalent
8
7
6
5
4
3
2
1
Expansion
Power
Output
Feedback
Start Input
X1
Auxiliary
Output
X2
Logic Input
S14
S24
Safety
Output
S34
S44
S54
SFL/SFLA user manual
PLC etc.
GND
Motor
Controller
Control Signal
MC1
MC2
MC1
MC3
MC2
MC4
M1
."
S14
Motor
Controller
MC3
MC4
M2