Setting the fence
square with the table
1. Make sure that the
electrical plug is removed
from the power point.
2. Push the saw arm (1) down
to its lowest position and
engage the release knob
(2) to hold the saw arm in
the transport position.
3. Loosen the mitre table lock
(15) (Fig. a).
4. Rotate the mitre table
(12) until the pointer is
positioned at 0º.
5. Tighten the mitre table lock
(15).
6. Using the 6mm hex key
provided, loosen the
four screws securing the
fence (11) to the base
(Fig. b).
7. Place a square against
the fence (11) and
alongside the blade
(Fig. c).
8. Adjust the fence (11) until it
is square with the blade.
9. Tighten the screws securing
the fence (11).
10. Loosen the Phillips head
screw holding the pointer
of the mitre scale (13)
and adjust it so that it
accurately indicates the
zero position on the mitre
scale (Fig. d).
a
b
c
11. Retighten the screw securing the mitre scale pointer.

Changing a blade

DANGER!
Never try to use a blade larger than the stated
capacity of the saw. It might come into contact with the
blade guards. Never use a blade that is too thick to allow the
outer blade washer to engage with the flats on the spindle.
It will prevent the blade screw from properly securing the
blade on the spindle. Do not use the saw to cut metal or
masonry. Ensure that any spacers and spindle rings that
may be required suit the spindle and the blade fitted.
1. Make sure that the electrical plug is removed from the
power point.
2. Push down on the operating
handle (3) and pull the
release knob (2) to
disengage the saw arm (1).
The release knob (2) can be
turned so that it is held in the
retracted position (Fig. e).
3. Raise the saw arm (1) to
its highest position.
4. Using a Phillips head screwdriver loosen and remove the
screw that secures the guard retraction arm (6) to the
rotating blade guard (Fig f).
5. Using a Phillips head screwdriver loosen and remove the
screw that secures the blade bolt cover (19) (Fig. g).
6. Pull the rotating lower blade guard (5) down then swing
it up together with the blade bolt cover (19). When the
14