■ Output operation mode
Out output of 1-stage preset model operates as same with the OUT2 output of 2-stage preset
model.
OUT1 output of 2-stage preset model is operated One-shot output or retained (Hold) output.
(except S, T, D of input operation mode)
OUT1 output could be set to 0 in all modes and 0 value output turns ON.
OUT2 output could not set to 0 in output operation mode: C, R, P, Q.
• Output type
One-shot output
Retained (hold) output
Output operation description in input operation mode
Mode
UP, UP - 1 / 2
RESET
999999
2-stage preset
1-stage preset
0
F
OUT1
OUT2 (OUT)
After count-up, counting display value increases or decreases until RESET signal is applied
and retained (hold) output is maintained.
RESET
999999
2-stage preset
1-stage preset
0
N
OUT1
OUT2 (OUT)
After count-up, counting display value and retained (hold) output are maintained until
RESET signal is applied.
RESET
999999
2-stage preset
1-stage preset
0
C
OUT1
OUT2 (OUT)
When count-up, counting display value will be RESET and count simultaneously.
OUT1 retained (hold) output will be OFF after OUT2 One-shot output time.
• The One-shot output time of OUT1 is regardless of OUT2.
RESET
999999
2-stage preset
1-stage preset
0
OUT1
R
OUT2 (OUT)
After count-up, counting value display is RESET after One-shot output time of OUT2 and it
counts simultaneously.
OUT1 retained (hold) output will be OFF after OUT2 One-shot output time.
• The One-shot output time of OUT1 is regardless of OUT2.
RESET
999999
2-stage preset
1-stage preset
0
K
OUT1
OUT2 (OUT)
After count-up, counting display value increases or decreases until RESET signal is applied.
OUT1 retained (hold) output will be OFF after OUT2 One-shot output time.
• The One-shot output time of OUT1 is regardless of OUT2.
RESET
999999
2-stage preset
1-stage preset
0
OUT1
OUT2 (OUT)
P
After count-up, counting display value is maintained while OUT2 output is on.
Counting value is internally RESET and counts simultaneously.
When OUT2 is OFF, displays counting value while OUT2 is ON, and it increases or
decreases.
OUT1 retained (hold) output will be OFF after OUT2 One-shot output time.
• The One-shot output time of OUT1 is regardless of OUT2.
RESET
999999
2-stage preset
1-stage preset
0
OUT1
Q
OUT2 (OUT)
After count-up, counting display value increases or decreases during OUT2 One-shot time.
OUT1 retained (hold) output will be OFF after OUT2 One-shot output time.
• The One-shot output time of OUT1 is regardless of OUT2.
RESET
999999
2-stage preset
1-stage preset
0
A
OUT1
OUT2 (OUT)
After count-up, counting display value and OUT1 retained (hold) output are maintained
until RESET input is applied.
• The One-shot output time of OUT1 is regardless of OUT2.
Find Quality Products Online at:
One-shot output Retained (hold) output Coincidence output
DN, DN - 1 / 2
UD - A / B / C
GlobalTestSupply
www.
Output operation description in input operation mode
Mode
UD - A / B / C
RESET
999999
2-stage preset
1-stage preset
0
S
-99999
OUT1
OUT2 (OUT)
OUT1 / 2 keep ON state in following condition:
Counting display value ≥ 1 / 2-stage preset value
RESET
999999
2-stage preset
1-stage preset
0
-99999
T
OUT1
OUT2 (OUT)
OUT1 output is off: counting display value ≥ 1-stage preset value.
OUT1 keeps ON state when 1-stage preset value = 0.
OUT2 keeps ON state in following condition: counting display value ≥ 2-stage preset value
RESET
999999
2-stage preset
1-stage preset
0
-99999
D
OUT1
OUT2 (OUT)
OUT1 / 2 are ON only when counting display value = 1 / 2-stage preset value.
• When setting 1 kcps for counting speed, solid state contact output should be used.
When using contact output, it is difficult to execute normal output operation due to
contact reaction time.
■ Counter operation of indicator model
Counting chart and output operation description
Mode
Input operation mode = UP, UP - 1 / 2
RESET
999999
TOTAL
0
Counting value increases or decreases until RESET input is applied.
When input is over max. / min. counting value, it displays 0.
When applying RESET input, displays 0.
RESET
999999
PRESET
HOLD
0
Counting value increases or decreases until RESET input is applied.
When input is reaching PRESET, the display
value is hold. When applying RESET input,
displays 0.
Mode
Input operation mode = UD - A / B / C
RESET
999999
-
0
-99999
■ Output operation for other conditions
01. Output operation for the relation of Start Point value, PRESET value
• Output operation description: 2-stage preset value > Start Point = 1-stage preset value
OUT1 occurs when RESET OFF.
• Output operation description: 2-stage preset value > Start Point > 1-stage preset value
Counting chart and output operation description
Mode
Input operation mode = UP, UP - 1 / 2
Change Start Point
RESET
2-stage preset
Start Point
1-stage preset
F
0
OUT1
OUT2
OUT1 does not execute.
OUT2 occurs when reaching 2-stage preset value.
02. 1-stage preset value ≥ 2-stage preset value (input operation mode: DN, DN-1, DN-2)
• Output operation description:
1-stage preset value > 2-stage preset value
Input operation mode
Mode
= DN, DN - 1 / 2
RESET
1-stage preset
2-stage preset
0
F
OUT1
OUT2
OUT1 does not execute.
.com
Input operation mode = DN, DN - 1 / 2
RESET
999999
0
-99999
When applying RESET input, displays 999999.
RESET
999999
PRESET
0
When input is reaching 0, the display
value is hold. When applying RESET input,
displays PRESET value.
Input operation mode = UD - A / B / C
Change Start Point
RESET
2-stage preset
Start Point
1-stage preset
0
OUT1
OUT2
Count down and OUT1 occurs when reaching
1-stage preset value.
• Output operation description:
1-stage preset value = 2-stage preset value
Input operation mode
Mode
= DN, DN - 1 / 2
RESET
1-stage = 2-stage
preset
0
F
OUT1
OUT2
OUT1 occurs when RESET OFF.