Autonics CTS Series Manuel du produit - Page 10

Parcourez en ligne ou téléchargez le pdf Manuel du produit pour {nom_de_la_catégorie} Autonics CTS Series. Autonics CTS Series 11 pages. Programmable digital counters / timers
Également pour Autonics CTS Series : Manuel (4 pages), Manuel (4 pages)

Autonics CTS Series Manuel du produit
Mode
Time chart and output operation description
• Memory retention parameter = CLR
POWER
INA (START)
INH (INHIBIT)
RESET
Setting time
Up
Display
Setting time
Down
• Memory retention parameter = REC
POWER
ONT.D
INA (START)
(On time
INH (INHIBIT)
display)
RESET
Setting time
Up
Display
Setting time
Down
• ON time indication mode of INA input
Time reset start operates when INA input turns ON.
Time progress stops while INA input is OFF.
If progress time is greater than setting time when INA input turns off, display value
flashes and operation stops until reset signal is applied.
■ 0 time setting
• It is available to set in output operation mode: OND, OND.1, OND.2, NFD, NFD.1.
• Output type
One-shot output
Retained (hold) output
Time chart at 0 time setting and operation description
Mode
Setting time 1 = 0
INA (START)
Setting time2
OND
0
OUT1
OUT2
INA (START)
RESET
Setting time2
OND.1
0
OUT1
OUT2
POWER
RESET
OND.2
Setting time2
0
OUT1
OUT2
Time chart at 0 time setting and operation description
Mode
Off_delay setting time = 0
INA (START)
RESET
On_delay
NFD
Up
0
Display
On_delay
Down
0
OUT2 (OUT)
INA (START)
RESET
On_delay
NFD.1
Up
0
Display
On_delay
Down
0
OUT2 (OUT)
■ Setting when 1-stage preset value > 2-stage preset value
• Output operation mode: OND, OND.1, OND.2
UP mode: OUT1 output does not turn ON.
DOWN mode: OUT1 output does not turn ON.
In 1-stage preset value = 2-stage preset value, when Start signal is
applied, OUT1 turns ON immediately.
Find Quality Products Online at:
0
0
0
0
One-shot output Retained (hold) output
Setting time 2 = 0
UP mode
DOWN mode
INA (START)
Setting time1
0
OUT1
OUT2
UP mode
DOWN mode
INA (START)
RESET
Setting time1
0
OUT1
OUT2
UP mode
DOWN mode
POWER
RESET
Setting time1
0
OUT1
OUT2
On_delay setting time = 0
INA (START)
RESET
Off_delay
Up
0
Display
Off_delay
Down
0
OUT2 (OUT)
INA (START)
RESET
Off_delay
Up
0
Display
Off_delay
Down
0
OUT2 (OUT)
GlobalTestSupply
www.

Segment Table

The segments displayed on the product indicate the following meanings. It may differ
depending on the product.
7 segment
0
0
I
1
1
J
2
2
K
3
3
L
4
4
M
5
5
N
6
6
O
7
7
P
8
8
Q
9
9
R
A
A
S
B
B
T
C
C
U
D
D
V
E
E
W
F
F
X
G
G
Y
H
H
Z
UP mode
11 segment
12 segment
I
0
I
0
I
0
I
0
I
J
1
J
1
J
1
J
1
J
K
2
K
2
K
2
K
2
K
L
3
L
3
L
3
L
3
L
M
4
M
4
M
4
M
4
M
N
5
N
5
N
5
N
5
N
O
6
O
6
O
6
O
6
O
P
7
P
7
P
7
P
7
P
Q
8
Q
8
Q
8
Q
8
Q
R
9
R
9
R
9
R
9
R
S
A
S
A
S
A
S
A
S
T
B
T
B
T
B
T
B
T
U
C
U
C
U
C
U
C
U
V
D
V
D
V
D
V
D
V
W
E
W
E
W
E
W
E
W
X
F
X
F
X
F
X
F
X
Y
G
Y
G
Y
G
Y
G
Y
Z
H
Z
H
Z
H
Z
H
Z
.com
16 segment
0
I
0
I
1
J
1
J
2
K
2
K
3
L
3
L
4
M
4
M
5
N
5
N
6
O
6
O
7
P
7
P
8
Q
8
Q
9
R
9
R
A
S
A
S
B
T
B
T
C
U
C
U
D
V
D
V
E
W
E
W
F
X
F
X
G
Y
G
Y
H
Z
H
Z