Autonics CX Series Manuel du produit - Page 5

Parcourez en ligne ou téléchargez le pdf Manuel du produit pour {nom_de_la_catégorie} Autonics CX Series. Autonics CX Series 11 pages. Lcd counter / timer

Autonics CX Series Manuel du produit
■ Timer parameter group
Parameter
Mark
Defaults
Counter /
T1-1
Timer
01)
C-T
COUNT
UP / DOWN
T1-2
mode
01)
U-D
Output
T1-3
operation
OUtM
mode
OND
01)
Counting
value
display part
s (defaults)
s
Time range
T1-4
s
01)
tRNG
s
m : s
m : s
m : s
Output ON
m
T1-5
time range
m
OnRNG
01) 03)
h : m : s
Output OFF
h : m
T1-6
time range
OFfRNG
h
01) 03)
OUT2
T1-7
output
HOLD [2-stage preset setting model]
OUT2
time
01) 04)
OUT1
T1-8
output
time
OUT1
0)10
01) 04)
OUT
T1-9
output
OUtT
time
HOLD
01) 04)
Input
T1-10
logic
05)
SIG
NPN
Input
T1-11
signal
IN-T
time
05)
Memorize
T1-12
counting
DATA
value
CLR
T1-13 Key LOCK
LOCK
lOFF
01)  When the setting value of the parameter is changed, all outputs are OFF and reset the current value when
returning to the RUN mode.
02) For CX6□-□P□ model.
03) T.ON, T.OFF setting values indicate the ON / OFF time range of OUT2 / OUT.
04)  In case of T1-3 Output operation mode: FLK.1, FLK.2, INTG, or T1-3 Output operation mode of 1-stage preset
setting model: OND, OND.1, OND.2,OND.3, T1-8 OUT1 output time is not displayed, T1-7 OUT2 output time is
displayed as OUT.T.
05)  In case of CX6□-□P□F model, T1-10 Input logic = NPN, T1-11 Input signal time = 25 ms are fixed, so these
parameters are not displayed.
Error Display and Output Operation
• When error occurs, the output turns OFF.
• When setting 1-stage preset value = 0, OUT1
output turns OFF.
In case of 2-stage preset value < 1-stage
preset value, OUT1 output is ignored and
only OUT2 output operates.
Output Operation Mode
For the detailed timing chart for operation output mode, refer to the manual.
Setting range
COUNT: counter,
TIME: timer
UP: 0 → setting time
DN: setting time → 0
UP
[1-stage preset setting model]
OND, OND.1, OND.2, OND.3, FLK,
FLK.1, FLK.2, INT, INT.1, OFD, NFD,
NFD.1, INTG, TOTAL
, ONT.D
02)
[2-stage preset setting model]
OND, OND.1, OND.2, OND.3, FLK,
FLK.1, FLK.2, INT, INT.1, INT.2, OFD,
NFD, NFD.1, INTG, TOTAL
, ONT.D
02)
Setting
value
Range
display part
999.999
0.001s to 999.999s
9999.99
0.01s to 9999.99s
99999.9
0.1s to 99999.9s
999999
1s to 999999s
99:59.99
0.01s to 99m59.99s
999:59.9
0.1s to 999m59.9s
9999:59
1s to 9999m59s
99999.9
0.1m to 99999.9m
999999
1m to 999999m
99:59:59
1m to 99h59m59s
9999:59
1m to 9999h59m
99999.9
0.1h to 99999.9h
0.01 to 99.99 sec, Hold
• When 10
digit is flashing, press [◀]
1
key once and Hold appears.
[1-stage preset setting model]
0.01 to 99.99 sec, Hold
• When 10
digit is flashing, press [◀]
1
key once and Hold appears.
[CX6□-□P□ model]
NPN, PNP
[CX6□-□P□ model]
1, 20 ms
• Min. signal width of INA, RESET,
20
INHIBIT, TOTAL RESET signal
CLR: Resets counting value when
power is off.
REC: Memorizes counting value at the
moment of power off.
(memory retention)
L.OFF: Unlock key LOCK
LOC.1: Locks [RESET] key
LOC.2: Locks [◀], [▲] key
LOC.3: Locks [RESET], [◀], [▲] key
Display
Description
Troubleshooting
Change the preset
Preset value = 0
value anything but
ERR0
0.

Input Connections

Display
• Input: CP1, CP2 (INHIBIT), SET
condition
• Max. counting speed in the contact input: 1 or 30 cps setting (counter)
-
■ No-voltage (NPN) input
• Solid-state input
-
Sensor
(NPN output)
Brown
-
Black
Blue
T1-3 Output
• Contact input
operation
mode:
Counter / Timer
OND,
+12 V
OND.1,
5.4 kΩ
OND.2,
OND.3,
Internal circuit
FLK.1,
of input part
FLK.2, INT,
INT.1, INT.2,
0 V
OFD, INTG,
TOTAL,
■ voltage (PNP) input
ONT.D
• Solid-state input
T1-3 Output
Sensor
operation
(PNP output)
Brown
mode: FLK,
NFD, NFD.1
Black
T1-3 Output
operation
mode:
Blue
OND,
OND.1,
• Contact input
OND.2,
Counter / Timer
OND.3
+12 V
-
Internal circuit
of input part
10.8 kΩ
-
0 V
-

Output Connections

• Solid-state output
-
Counter / Timer
-
A:
When using inductive load (relay etc.), surge absorber (diode, varistor etc.) must be connected
-
between both sides of the load.
• Contact output
Counter / Timer
LOAD
Sold Separately: Terminal Cover
• Unit: mm, For the detailed drawings, follow the Autonics website.
RSA-COVER: DIN W48 × H48
3
□48.4
Sensor
Counter / Timer
(NPN open collector output)
+12 V
5.4 kΩ
Internal circuit
of input part
0 V
Sensor
Counter / Timer
(PNP open collector output)
+12 V
Internal circuit
of input part
10.8 kΩ
0 V
A
LOAD
(+)
Power
for load
(DC)
(-)
(Power of load)
RMA-COVER: DIN W72 × H72
22
4
13
Counter / Timer
Brown
+12 V
5.4 kΩ
Black
Internal circuit
of input part
Blue
0 V
Counter / Timer
Brown
+12 V
Black
Internal circuit
of input part
10.8 kΩ
Blue
0 V
70
10