Please read and save these instructions. Read carefully before attempting to assemble,
install, operate or maintain the product described, protect yourself and others by observ-
ing all safety information. Failure to comply with instructions could result in personal injury
and/or property damage! Retain instructions for further reference.
DynaQuip Automatic Drain Valves
DynaQuip automatic drain valves are motorized ball valves, used to automatically drain water,
oil and small debris from filters, tanks, drain legs, after-coolers and receivers.
SPECIFICATIONS
Adjustable cycle time
Max. working pressure
Ambient temperature
Enclosure
Voltage
Current
Valve construction
Seals
Discharge volume
Power adaptor
Full-Port ball valve
Discharge time
General Safety Information
Do not apply electrical power to the unit unless the unit is fully assembled and mounted. Failure
to do so could result in personal injury and/or damage to the unit. Disconnect power source and
depressurize the system before working on the unit. Failure to do so could result in personal
injury. The downstream or discharge side of the ball valve must be directed to a safe area for
collecting water, oil and debris. The compressed air system is pressurized during operation.
Appropriate precautions are recommended.
CAUTION:
It is recommended that eye protection be worn while servicing the system.
Failure to do so could result in personal injury.
WARNING:
The motorized drive unit case is not capable of supporting any loads. Do not
attempt to use the unit as a step. This will cause damage to the unit and could cause
personal injury. Do not use in hazardous locations.
CAUTION:
Do not use the case as leverage when mounting this unit or tightening fittings.
Use the wrenching flats on the valve body.
Installation
Figures 2 and 3 show typical installations of the drain valve. It is recommended that the
motorized drive be removed from the valve before piping the valve into your system. Then
reinstall the motorized drive unit to the valve. This can be done using the four screws holding
the valve to the case.
1. Install the automatic drain valve to the compressed air system at a point where moisture
would tend to collect.
2. Pipe the opposite end of the valve to your discharge area.
To order or for additional information, visit dynaquip.com or call 800-545-3636.
2
Operating Instructions and Parts Manual
1 min – 14 days
200 PSIG
35°F to 165°F
NEMA 4
12VDC
0.83 Amps
Lead Free brass NSF/ANSI 372
Reinforced Teflon
½"= 3.1, ¾" = 6.0, 1" = 7.7, 1¼" = 12.8 (gal. per cycle @ 80 PSI)
120V AC 20'
½" NPT including ¼" NPT reducer bushings, ¾", 1", 1¼" NPT
7 seconds non-adjustable
5.0"
5.33" (½)
5.88" (¾)
6.20" (1)
6.80" (1¼)
Figure 1
3.75"