DynaQuip WaterCop Pro WPACT12V Manuel de démarrage rapide - Page 4
Parcourez en ligne ou téléchargez le pdf Manuel de démarrage rapide pour {nom_de_la_catégorie} DynaQuip WaterCop Pro WPACT12V. DynaQuip WaterCop Pro WPACT12V 4 pages.
Également pour DynaQuip WaterCop Pro WPACT12V : Manuel du propriétaire et manuel d'installation (16 pages)
RJ45 Connection
for security/automation
integration and/or use with
wall switch and CAT5E cable
Classic and Pro
Interface Contacts
1 - - - - - - - - - - - - 8
7
Brown/White (5VDC)
5 Blue/White (to close)
6 Green (to open)
CAT5-E
3
Green/White
4
Blue
RJ45 Socket
2 Orange
Power Supply (20' Cable)
Note polarity striped wire
is attached to +12V terminal
WPACT12V Actuator
1 Black
2 Red
3 Green
4 Brown or Yellow
5 White
6 Blue
P/N WPACT12V
P/N WPACT12V
watercop.com
St. Clair, MO 63077
To order or for additional information, visit watercop.com or call 800-545-3636.
To order or for additional information, visit watercop.com or call 800-545-3636.
WPC & WPCH
ON
MAIN WATER
CONTROL
OFF
WIRING GUIDE
1
2
3
4
5
6
1
REMOTE VALVE
12V RLY ALARM TROUBLE
WPACT12V
available with
25, 50 or 75' cable
B
E
1
2
3
4
5
6
1
2
1
2
1
2
REMOTE VALVE
12V RLY
ALARM TROUBLE
2
1
2
1
2
Dry contact closure signal to security panel during alerts
An alert is a problem with a sensor. A probe is shorted,
open or low battery is detected. Water is not shut off.
Dry contact closure signal to security panel during alarms
An alarm is a water shut-off due to a sensor detecting water and
activating the system. There is no alarm signal if the valve is
closed by an input from the security panel or the WaterCop panel.
12 VDC Signal when the unit displays
water is off for use with remote relay
Jumper wire
between 2 & 4
1
2
3
4
REMOTE VALVE
Note: When using WPC or WPCH to only control a remote replay
(no WPACT12V attached) jumper wires must be attached as shown
Hardwired Sensor
(10' cable) attached here
C
Jumper wire
between 3 & 5
1
2
1
2
1
2
5
6
12V RLY ALARM TROUBLE
DQ PART NUMBER 192456 REV E
Made in the USA