Autonics BD Series Manuel - Page 2
Parcourez en ligne ou téléchargez le pdf Manuel pour {nom_de_la_catégorie} Autonics BD Series. Autonics BD Series 14 pages. Laser displacement sensors amplifier unit
Également pour Autonics BD Series : Manuel du produit (6 pages), Manuel du produit (5 pages), Manuel du produit (3 pages)
-|Transparent setting
▣ Specifications
Sensor Head
Model
BD-030
Near
(25mm)
Spot diameter
(unit: ㎛)
Approx.
290×790
1 ㎛
Resolution
※1
Reference
30mm
distance
Maximum
measurement
20-40mm
range
0.1% F.S.
Linearity
※1※2
(in 25 to 35mm)
Temperature
0.05% F.S./℃
Characteristics
※3
Power supply
-
※4
Red semiconductor laser (wavelength: 660nm, IEC 60825-1:2014)
Optical
Diffuse reflection
method
Class 1 (IEC/EN),
Laser class
Class I (FDA(CDRH) CFR Part 1002)
Output
Max. 300㎼
Operation
Power indicator: red LED, Laser emission indicator: green LED, NEAR/FAR indicator: green LED
indicators
Connection
Connector type
Insulation
Over 20MΩ (at 500VDCᜡ megger)
resistance
Noise immunity
Square shaped noise by noise simulator (pulse width: 1㎲) ±500V
Dielectric strength 1,000VAC 50/60Hz for 1 minute
Vibration
1.5mm amplitude at frequency of 10 to 55Hz (for 1 min) in each X, Y, Z direction for 2 hours
Shock
300m/s
Ambient
Max. Incandescent lamp 10,000㏓
illumination
Ambient
-10 to 50℃, storage: -15 to 60℃
temperature
Ambient
Under 85%RH, storage: under 85%RH
humidity
Protection
IP67 (IEC Standards, except connector of extension cable)
structure
Material
Case: Polycarbonate, Sensing part: Glass, Cable: Polyvinyl chloride
Amplifier unit
BD Series amplifier unit: 1
compatibility
Accessory
Ferrite core (made by TDK co. ZCAT2132-1130), Mounting bracket, Bolt, Nut
Approval
Weight
Approx. 209g (approx. 56g)
※5
※1: When measuring fixed non-glossy white paper (reference temperature: 25℃, reference distance, response time: 1ms, average
128 times).
※2: Value indicates the error with respect to the ideal straight line and the numbers in parentheses are the rated measurement
ranges guarantee linearity.
※3: Value measured by using an aluminum jig fix the sensor head and non-glossy white paper.
※4: Using power from the amplifier unit.
※5: The weight is with packaging and the weight in parenthesis is only unit weight.
※The temperature or humidity mentioned in Environment indicates a non freezing or condensation environment.
guide|-
Reference
Far
(30mm)
(35mm)
Approx.
Approx.
240×660
190×450
(Approx. 30G) in each X, Y, Z direction for 3 times
2
Laser Displacement Sensor
BD-065
Near
Reference
Far
(55mm)
(65mm)
(75mm)
Approx.
Approx.
Approx.
360×1590
290×1180
210×830
2 ㎛
65mm
50-80mm
0.1% F.S.
(in 55 to 75mm)
0.06% F.S./℃
Class 2 (IEC/EN), Class II (FDA(CDRH) CFR Part 1002)
Max. 1㎽
Approx. 233g (approx. 68g)
BD-100
Near
Reference
Far
(80mm)
(100mm)
(120mm)
Approx.
Approx.
Approx.
480×1870
410×1330
330×950
4 ㎛
100mm
70-130mm
0.15% F.S.
(in 80 to 120mm)
Approx. 233g (approx. 68g)
E-7 -7