Smart-Charge-
The
Product operation:
1. Constant Current (C.C.) LED flashing - Soft Start, from 20 seconds
to 2 minutes depending on the condition of the batteries.
2. Constant Current LED on solid – Full available current being
delivered.
3. C.C. LED on solid and Constant Voltage (C.V.) LED flashing –
Regulator is in transition from C.C. to C.V.
4. C.V. LED on solid – Regulator is in Constant Voltage mode and is
being timed. Time is determined by a calculation that was made
during C.C.
5. Float LED on solid – Regulator is in Float mode.
6. Float LED flashing – Regulator is in Force to Float. (see #12 below)
7. Over voltage LED on solid – regulator has seen voltage above
15.5(31.0) volts and has switched off the field.
8. Battery Over Temp LED flashing – no temp sensor or bad temp
sensor connection.
Mark Grasser – DC Power Solutions, LLC.
New
EIGHT Algorithms for Lead Acid, TWO Algorithms for LFP.
New
Better resistance to water intrusion.
New
Easy to access connector for temp sensors and remote.
New
Temp sensors that allow for better control of alternator
output vs temperature.
New
Optional panel mount remote duplicates the six LEDs and
Force to Float button of the R210a.
As always
Battery and alt. temp sensors included at no cost.
As always
Two year warranty covering any manufacturing defects.
As always
Designed and manufactured in Eliot, Maine. USA.
406 Harold Dow Hwy, Eliot, ME. 03903
R210a