Autonics LSE-4A5R2 Manuel - Page 2

Parcourez en ligne ou téléchargez le pdf Manuel pour {nom_de_la_catégorie} Autonics LSE-4A5R2. Autonics LSE-4A5R2 12 pages. 2d laser scanners
Également pour Autonics LSE-4A5R2 : Manuel du produit (5 pages)

LSE-4A5R2

▣ Specifications

Model
Power supply
Allowable voltage range
Laser class
Emitting
property
Wavelength band
Max. pulse output power 75W
Angular resolution
Aperture angle
Object reflectivity
Scanning mode
※ 1
Monitoring zone
Min. size of the scanning target
Power consumption
※ 2
Response time
Input
Output
Laser scanner angle
Instal-
lation
Bracket rotation angle
※ 3
angle
Bracket tilt angle
Front contamination
※ 5
Communication interface
Life expectancy
Insulation resistance
Dielectric strength
Vibration
Shock
Ambient illumination
Environ
Ambient temperature
ment
Ambient humidity
Material
Protection structure
Power, I/O
Cable
Ethernet
Accessory
Component
PC program
Korean Railway Standards
Approval
※ 7
Weight
※ 1: The monitoring zone may be changed by the sensitivity level setting.
※ 2: 'Monitoring time' is able to be set with the remote control or atLidar.
※ 3: Please refer to '▣ Installation'.
※ 4: It represents alignment range of laser scanner and is able to be set within the range from -5 to 5 based on the mark line.
※ 5: It is used for setting sensor positions, parameters, and monitoring status information.
※ 6: Ambient temperature in power supplied status is -30 to 60℃ and in power cut status is -10 to 60℃.
※ 7: The weight includes packaging. The weight in parenthesis is for unit only.
※ The temperature or humidity mentioned in Environment indicates a non freezing or condensation.
D-4
LSE-4A5R2
24VDCᜡ
80 to 120% of rated voltage
Infrared laser
CLASS 1
905nm
0.4°
90°
Min. 2%
Motion and presence
0.3×0.3m to 5.6×5.6m (object reflectivity: at approx. 10%)
ㆍAt detection distance of 3m: approx. W2.1×H2.1×L2.1cm
ㆍAt detection distance of 5m: approx. W3.5×H3.5×L3.5cm
ㆍObject reflectivity: 90% (at Kodak Gray card R-27, white)
Max. 8W
Typ. 20 to 80ms+monitoring time
Photocoupler input: 1 (output test mode)
ㆍ[H]: min. 8VDCᜡ (max. 30VDCᜡ), [L]: max. 3VDC
ㆍ [H] operates as output test mode and outputs obstacle detection output and error status output
PhotoMOS relay output: 2 (obstacle detection output, error status output)
ㆍGalvanic isolation, non-polarity
ㆍ30VDC / 24VAC, max. DC80mA (resistive load)
ㆍOutput resistance: 30Ω
ㆍSwitching time: t
=5ms, t
ON
-45 , 0 , 45°
※ 4
-5 to 5°
-3 to 3°
Normal operation with max. 30% contamination of one material
Ethernet
Max. 6.8 years (60,000 hours)
Over 5MΩ (at 500VDC megger)
500VAC 50/60Hz for 1 minute
2
Max. 2G (18.7m/s
)
30G/18ms
Sunlight: max. 100,000lx
※ 6
-30 to 60℃
0 to 95%RH, storage: 0 to 95%RH
Polycarbonate
IP67 (IEC standard)
Ø5mm, 8-wire, 5m
(AWG 26, core diameter: 0.16mm, number of cores: 7, insulator out diameter: Ø1mm)
Ø5mm, 4-wire, 3m, shielded cable
(AWG 26, core diameter: 0.16mm, number of cores: 7, insulator out diameter: Ø1mm)
Bracket, M2.6×L6 Tapping screw (for fixing bracket rotation angle): 2, 3mm allen wrench
atLidar (laser scanner program)
KRS SG 0068
Approx. 0.96kg (approx 0.58kg)
=5ms
OFF