Autoplugin RCP-V2 Manuel d'installation - Page 8
Parcourez en ligne ou téléchargez le pdf Manuel d'installation pour {nom_de_la_catégorie} Autoplugin RCP-V2. Autoplugin RCP-V2 8 pages. Volvo
4
Time limits
exceeded
5
Unsuccessful
start
6
Operation
cycle too
short
8
CAN-bus
error
9
Settings error Settings have been
11
Heater no
connection
12
Unknown
CAN-bus
* Information available on request
© Autoplugin ES
8
Time limit for
autonomous operation
of the heater is
achieved (with applied
setting 1.1)
The heater was
switched off
spontaneously at
startup
The heater was
switched off
spontaneously with
operating time of less
than 20 minutes
The lines X2.9 и X2.10
connected incorrectly
incorrectly stored in
RCP's memory
The heater is
unplugged from CAN-
bus or is out of order
CAN-bus type has not
been determined
Run the engine or cancel 1.1
setting
Make diagnostics of the heater
if the error appears again
Make diagnostics of the heater
if the error appears again
Check the lines connection
Reset the settings (8.1.1),
readjust RCP
Make diagnostics of the heater
Check for compatibility of RCP
module with the car. Try to set
the CAN-bus code manually*