Assembly Instructions
CAUTION: The blade assemblies must be
mounted on the motor assembly so that the
raised lip edge is facing up.
1. Rotate the motor hub so the notched area is above
the screw hole in the motor hub. Install one blade
assembly on the top of the motor assembly using
two M6 x 12mm pan head screws and two M6
lockwashers (supplied) (Figure 1). Repeat this
procedure for the remaining two blade assemblies.
REVERSING SWITCH
M6 x 12mm PAN HEAD
SCREW
M6 LOCKWASHER
BLADE
ASSEMBLY
FLAT AREA OF
MOTOR HUB
MOTOR ASSEMBLY
Figure 1
2. Remove the two setscrews from the top of the
motor coupler (Figure 1). Retain the setscrews for
future use.
3. Route the two motor leads through the center hole
in the motor cover. Place the motor cover over the
motor by aligning the reversing switch hole in the
cover over the reversing switch as shown in Figure
2. Secure by installing three M5 x 10mm pan head
screws and three M5 external tooth lockwashers
(supplied) (Figure 2).
M5 x 10mm PAN HEAD
SCREW (3)
M5 EXTERNAL TOOTH
LOCKWASHER (3)
MOTOR COVER
Figure 2
4. Remove the hanger ball by loosening the setscrew
in the hanger ball until the ball falls freely down the
downrod (Figure 3). Remove the pin from the
downrod, then remove the hanger ball. Retain the
pin and hanger ball for reinstallation in Step 9.
Figure 3
REMOVE
SETSCREW (2)
5. Separate, untwist and unkink the two motor leads,
then route them through the hanger ball/downrod
assembly and seat the downrod in the motor
coupler (Figure 4).
6. Align the clevis pin holes in the downrod with the
holes in the motor coupler. Install the clevis pin and
secure with the hairpin clip (Figure 4). The clevis
pin must go through the holes in the motor coupler
It is critical that the clevis pin in the motor coupler is
properly installed and the setscrews securely
tightened. Failure to verify that the pin and
setscrews are properly installed could result in the
fan falling.
7. Install two setscrews (previously removed in
Step 2) in the motor coupler (Figure 4). While
pulling up on the hanger ball, securely tighten both
setscrews.
It is critical that the clevis pin in the motor coupling
is properly installed and the setscrews securely
tightened. Failure to verify that the pin and setscrews
are properly installed (as shown in Figure 4) could
result in the fan falling.
MOTOR COVER
Figure 4
4
PIN
HANGER
BALL
DOWNROD
WARNING
HAIRPIN
CLIP
REPLACE
SETSCREW (2)
SETSCREW
DOWNROD
MOTOR
COUPLING
CLEVIS
PIN
Model No.: ACF765