DCP LogIT DataMetern1000 Manuel d'instruction - Page 2

Parcourez en ligne ou téléchargez le pdf Manuel d'instruction pour {nom_de_la_catégorie} DCP LogIT DataMetern1000. DCP LogIT DataMetern1000 13 pages.

DataMeter 1000 Technical specifications
•Physical
Size
155 x 92 x 34mm
Mass
240g
Case material
ABS with back printed splash proof polyester keyboard
•Electronic
LCD display
2 X 16 character STN technology
Operating system
SCC Research LOGOS 2
Sensor system
DCP Microsense
Memory
16K E
non volatile memory for data + system
2
Analogue capture
10mS on all three sensors (software dependent)
Analogue resolution
10bit + averaging
Digital event timing
64µS on all three sensors (software dependent)
Battery
Built-in NiMH rechargeable battery
Power requirements
9-14 volts DC maximum
Acknowledgments
The designers express grateful thanks to the following for their help and support
throughout the development of DataMeter:
Dick Cianchi
Viv Cousins
Copyright
The rights of this book are the property of the author and the publishers DCP
Microdevelopments Limited. It may only be reproduced by the owner for
instructional use with LogIT and not in whole or part in any other publication
without prior permission from the publishers. The original artwork was produced
on an Apple Macintosh 8500/150 with an Apple 600dpi laser printer. DataMeter,
LogIT, LIVE, SwitchIT, AlarmIT, CheckIT and Microsense
Microdevelopments. AutoLog is a trademark of SCC Research. All other trade
marks acknowledged.
Disclaimer
The LogIT designers and software publishers cannot be held liable for any special,
incidental, consequential, indirect or similar damages due to loss of data, loss of
business profits, business interruption or any other reason, resulting from the use of
LogIT products, even if they have been advised of the possibility of such
damages.
LogIT DataMeter 1000 is a joint British development between
DCP Microdevelopments and SCC Research
Fourth edition
Electromagnetic compatibility declaration
The LogIT system and accessories are designed for use as education and training
equipment. The use of this apparatus outside the classroom, laboratory, study area or
similar such place invalidates conformity with the protection requirements of the EEC
Electromagnetic Compatibility directive (89/336/EEC) and could lead to prosecution.
sensor system
®
Neil Dyer
Joy Palmer
are trademarks of DCP
®
© David Palmer 1999
24
Contents
Overview
In Detail
Programmed logging
Setting the internal Time and Date clock
Advanced Programming
Downloading the stored data
Timing
DataMeter in Control
Reference
DataMeter in education
Sensors
Sensor product range
Datalogging and System Software
Problems?
Technical specifications & acknowledgments
1
2
4
5
6
7
9
10
11
12
13
13
14
15
16
17
19
20
21
22
23
24