7
Technical specifications
Routine maintenance:
Cleaning:
Voltage:
Current:
Temperature range:
Humidity:
Environmental protection:
Impact rating:
Unit dimensions:
Maximum number of readers
on one HBUS cable:
The reader is idle.
1
Peak current during card read.
2
Gallagher T Series readers are UL humidity tested and certified to 85% and have been independently
3
verified to 95%.
Note: The current values stated above have been reported using the default configuration for a reader
in Command Centre. Changing the configuration may vary the current value.
3E4289 Gallagher T11 Reader | Edition 1 | August 2016
Copyright © Gallagher Group Limited
Not applicable for this reader
This reader should only be cleaned with a clean, lint free, damp cloth
9 Vdc - 16 Vdc
Mifare Reader
Idle
1
at 9 Vdc
124 mA
at 13.6 Vdc
84 mA
-35 °C to +70 °C
Note: Direct sunlight may increase the internal reader temperature
above the ambient temperature level
0 - 95% non-condensing
IP68
IK07
Height 115 mm (4.5")
Width 70 mm (2.8")
Depth 12 mm (0.5")
20
Multi Tech Reader
Maximum
Idle
2
175 mA
115 mA
113 mA
100 mA
3
Maximum
1
2
164 mA
124 mA
Page 11