BACKDRAFT
DAHPER:
We recommend
that a backdraft
damper
be used in all Vent Hood installations.
Cold weather
installa-
tions necessitate
the use of a backdraft
damper
to minimize the flow of cold air into the room. A non-
metallic thermal
break should also be installed to minimize conduction
of outside
temperatures
through
the ductwork.
Locate the thermal
break as close as possible
to where the ducting enters
the
heated
portion
of the house.
PLANNING
THE INSTALLATION:
Before beginning installation of theVent
Hood andVentilator,
PLAN OUT the entire
installation proce-
dure beforehand,
considering
the following areas:
I. HOOD
SIZE & LOCATION-
(The hood should be as wide or wider than the cooldng
appliance with
the hood being centered
on the appliance.Vertically,
the bottom
of the hood should be between
30"-
36" above the appliance
cooldng surface).
2. DUCTING-
(ducting transitions,
air flows to outside?
Use of Backdraft
damper?
...etc.)
3. ELECTRICAL REQUIREMENTS-
( 120Volts, 60 Hz, 15 AMP Service, Local Codes...etc.)
4.ADEQUATE
MOUNTING
SURFACES- (location
of wall studs, additional
support
for safe wall
mounting...etc.)
0
HANDLING
NOTE-
This Hood has been inspected prior to shipping to be free of defects. Due to the
weight of the Vent Hood and Ventilator and to prevent scratching or denting the unit, we recommend the use of
two installers to move, place, and secure the Vent Hood to avoid personal injury or damage to the Hood.
INNER
LINER REHOVAL:
The DCS Professional Vent Hood has been designed into (2) major assemblies to accommodate
easy
and safe installation. The following procedure
is best done with the Hood on its back on a padded sur-
face. The inside liner assembly can be separated from the outer hood assembly by removing the (I 2)
inner perimeter
screws- (3 each side/front/back).
Once these screws have been removed, the liner
assembly can slide down to gain access to the male/female disconnect plug- See Fig.8 on page 5.After
the disconnect plug has been unplugged, the liner assembly can be set aside until the hood has been
installed into the soffit or wall.
HODEL
IDENTIFICATION:
DCS-VH-36HS (w/Heat Lamps)
DCS-VH-36S (standard)
DCS-VH-48HS (w/Heat Lamps)
DCS-VH-48S (standard)
DCS-VHI2-36HS (w/Heat Lamps)
DCS-VH 12-36S(standard)
DCS-VH-30HS (w/Heat Lamps)