9.Reverse output: This function works for the cooling system. When the temperature are higher
than set temperature, the thermostat will disconnect the cooling system, otherwise, it will
connect the cooling system.
10.Parameter initialization: All setting parameters are restored to default values.

TROUBLESHOOTING

Fault Codes
E1 = Built-in sensor short-circuit or disconnected.
E2 = Floor sensor short-circuit or disconnected.
Note: Should a sensor fault display, please connect us for assistance.
DIMENSION (MM)
87
13
42
60
16
26
51

INSTALLATION AND WIRING INSTRUCTIONS

Installation
Loosen fixing screw on the base of
the thermostat and separate front
panel from back section.
Step 1
Wire the back section as shown in
the wiring diagram.
Step 2
14