Emerson CSB400 Series Fiche d'installation - Page 3
Parcourez en ligne ou téléchargez le pdf Fiche d'installation pour {nom_de_la_catégorie} Emerson CSB400 Series. Emerson CSB400 Series 8 pages. Balance port and stem/ stem guide change-out procedure
new balanced
port assembly
Step 5. Remove new balance port assembly from repair kit. Verify the new balance port assembly has a green stripped
spring. If it does not have a green stripped spring, it is an old balance port assembly and should not be used. O-rings
will come well-lubed with Dow Corning
during handling, re-apply Dow Corning
new balanced
port assembly
Step 6. Install the new balance port assembly into the body with the pitot tube pointing into the downstream side of
the regulator body. Press firmly to ensure a secure fit, but take care not to pinch the housing O-ring.
Dow Corning
is a registered trademark owned by Dow Corning Corporation.
®
pitot tube
33 and installed on the balance port assembly. If lubrication has been lost
®
33 or comparable extreme low temperature lubricant.
®
green stripe
spring
pitot tube pointing
dowstream side
CSB400 Series
O-ring
press firmly
green stripe
spring
3