Galletti MSA 5 999 H Manuel de l'utilisateur - Page 15

Parcourez en ligne ou téléchargez le pdf Manuel de l'utilisateur pour {nom_de_la_catégorie} Galletti MSA 5 999 H. Galletti MSA 5 999 H 16 pages. Multisplit with high wall indoor units

Galletti MSA 5 999 H Manuel de l'utilisateur
MSA - MSA 5
10.1
Before you ask for servicing or repairs, check the following points.
SYMPTOMS
The fan speed can not be changed.
SYMPTOMS
The remote control signal is not transmitted even
when the ON/OFF button is pushed.
SYMPTOMS
The TEMP. indicator does not come on.
SYMPTOMS
The indication on the display disappears after a lapse
of time.
The TIMER indicators go off after a lapse of certain
time.
SYMPTOMS
No receiving tone sounds from the indoor unit even
when the ON/OFF button is pushed.
È severamente vietata la riproduzione anche parziale di questo manuale / All copying, even partial, of this manual is strictly forbidden

TROUBLES AND CAUSES (CONCERNING REMOTE CONTROLLER)

SETTING CHANGE IS IMPOSSIBLE
CAUSES
- Check whether the MODE indicated on the display
is "AUTO"
- Check whether the MODE indicated on the display
is "DRY"
THE TRANSMISSION INDICATOR "
CAUSES
- Check whether the ON TIMER is indicated on the
display.
THE DISPLAY NEVER COMES ON
CAUSES
· Check whether the MODE indicated on the display
is "FAN ONLY".
THE DISPLAY GOES OFF
CAUSE
- Check whether the timer operation has come to an
end when the OFF TIMER is indicated on the
display.
- Check whether the timer operation is started when
the ON TIMER is indicated on the display.
THE SIGNAL RECEIVING TONE DOES NOT SOUND
CAUSES
- Check whether the signal transmitter of the remote
controller is property directed to the receiver of the
indoor unit when the ON/OFF button is pushed.
15
REASON AND DISPOSAL
When the automatic mode is selected, the air
conditioner automatically selects the fan speed.
When dry operation is selected, the air conditioner
automatically select the fan speed. The fan speed
can be selected during "COOL" and "FAN ONLY"
and "HEAT" (cooling only type without)
" NEVER COMES ON
REASON AND DISPOSAL
The remote control signal is not transmitted, because
the air conditioner is off.
REASON AND DISPOSAL
The temperature cannot be set during fan only
operation.
REASON AND DISPOSAL
The air conditioner operation stops since the set
time elapsed.
When the time set to start the air conditioner is
reached, the air conditioner will automatically start
and the appropriate indicator will go off.
REASON AND DISPOSAL
Direct the signal transmitter of the remote controller
to the receiver of the indoor unit, and then rapidly
push the ON/ OFF button twice.