ENERGY SAVING TIPS:
Eliminate air currents in the liner vicinity by shutting nearby windows and doors, turning off ceiling fans and adjusting
the adjacent heating and air conditioning outlets if necessary. Place your largest pans on the rear burners whenever
possible. Clean filters and grease laden surfaces often to improve efficiency. Always use lids on cookware to retain
heat and moisture. Minimize the amount of liquid used to cook food. Select cookware of proper size, material and
construction for the cooking task being performed.
CARE & CLEANING:
Proper cleaning is necessary to maintain performance and appearance, while also ensuring safe operation. The frequency
of cleaning should be according to the type and amount of cooking. Best results will be achieved by cleaning soiled
components as soon as possible. Filters must be cleaned regularly.
Filter Removal: Each filter has two aluminum cylindrical knobs, one towards the rear and one towards the front. The
front & rear knobs are only for grasping and are permanently connected to the filter. To remove the filter, grasp the
front & rear knobs, push the filter backwards towards the rear of the hood until the front of the filter drops down.
Grasping the filter, remove it from the rear by now pulling it forward.
The filters may be cleaned by hand washing in hot water using a mild detergent solution or by placing in an automatic
dishwasher. Place filters with side holes facing vertical so detergent enters top and grease exits bottom.
CAUTION: Most common scrubber type pads will scratch the liner. If a commercially available
stainless steel cleaner is used, it is important to read the labels for chlorine compounds. Chlorine is a corrosive
substance. If these compounds are present, rinse thoroughly and dry with a soft lint-free cloth. Follow polish
manufacturer's instructions. Always wipe stainless steel surfaces with the grain. Never wipe across the grain.
After cleaning, reinstall the filters carefully.
LED LIGHT BULBS:
®
CopperSmith
liners
watt, 350 lumen, and 3000K (color temperature).
Lowe's, McCoy's, Menards, Ace True Value and Home Depot.
PART 4
Electrical Connection
IMPORTANT: Copy this page and the next pages for your electrical installer.
For unit amperage see diagram 1 (page 7)
WARNING! Ensure that the power supply is disconnected before proceeding. Verify that the power supply
matches the ratings found on the appliance data label before proceeding. The complete appliance must be properly
grounded at all times when electrical power is applied. Do not ground the appliance with the neutral (white) house
supply wire. A separate ground wire must be utilized. Failure to complete electrical connections properly may result in
damaged or non-functional systems. Follow instructions carefully to ensure proper installation.
It is the owner's responsibility to ensure that a qualified person performs the electrical connection of this appliance.
The electrical installation, including minimum supply wire size, must comply with the National Electric Code
ANSI/NFPA 70-1990 (or latest revision) and local codes and ordinances. A copy of this standard may be obtained
from: National Fire Protection Association, 1 Batterymarch Park, Quincy, Massachusetts 02269-9101.
INSTRUCTIONS: A 15 to 20 amp electrical service is recommended for proper electrical supply. Before determining,
calculate amp ratings based on the product label found on the liner and the ventilator. Always observe local building
codes. Always use a dedicated circuit. Line load is calculated by adding the amperage of the LED lights to the rated
amperage of the ventilator (either in-line or roof top). If the ventilator is rated in watts rather than amps, divide the watts
by 120 and this will give you the amperage rating. The CopperSmith
fan control. Make sure the rated amperage on the ventilator does not exceed 6.0 amps (or 700 watts).
Revised 05/15/20
are designed for MR16/GU10 LED flood light bulbs. The bulbs provided with the unit are 3.5
They can be purchased at most home or grocery stores, e.g.,
®
liner is supplied with a 6.0 amp variable speed