Galls K9 Partner Manuel d'instruction - Page 15

Parcourez en ligne ou téléchargez le pdf Manuel d'instruction pour {nom_de_la_catégorie} Galls K9 Partner. Galls K9 Partner 20 pages. Power door opener

K9 Partner Power Door Opener System with PowerTouch Remote Control
Trouble Shooting Guide - K9 Partner Door Opener
If a component such as the receiver, transmitter, actuator, or gas strut should
fail; DO NOT remove the entire kit. Remove ONLY the failed component for
repair or replacement.
Use a digital or analog voltmeter to check power and voltage! Do NOT use a test light!
Symptom
1.0 No output from one
or more channels on
remote control receiver
Symptom
2.0 Signal transmitted
and received, but no
operation.
Possible Cause
1.1 No signal from
transmitter
1.2 One or both of the
outputs have failed
1.3 Receiver outputs ok,
but relays or equipment
do not operate
Possible Cause
2.1 No signal from
transmitter
2.2 One or both of the
outputs have failed
2.3 Receiver has failed
outputs
Corrective Action
1.1a Verify that transmitter is sending a signal and
that transmitter is coded correctly. See symptom
4.00.
1.1b Check status light on transmitters. Should
be bright red.
1.1c Check transmitter battery. Should be +12v
and drop 0.2 - 0.3 volts when button is pressed.
1.2a Press each transmitter button in sequence.
While pressing button, use only a voltmeter probe
to check each corresponding output
(Violet or Green/black = button 'A')
(Pink or Yellow/black = button 'B').
1.2b If checking voltage, a ground signal is
present when button is pressed and float when not
pressed.
1.2c If checking ohms, the outputs should read 9-
ohms when button is pressed and 0- ohms when
not pressed.
1.2d If outputs read nothing when pressed or not
pressed, then the power supply is damaged.
1.2e Send back to factory for repair or
replacement.
1.2f Any of the above problems can be caused by
a defective unit or damage by the customer from
over-voltage, over-current or testing the inputs
and outputs using a test light instead of a
voltmeter.
1.3 Check wire and equipment for problem.
Corrective Action
2.1 See section 4.00
2.2a Check wire harness for loose connections or
damaged wires or terminals.
2.2b Check equipment for problem in motors or
relays.
2.3 Recheck section 1.0.
Manual C840.N2