Galltec+mela DW Manuel - Page 4
Parcourez en ligne ou téléchargez le pdf Manuel pour {nom_de_la_catégorie} Galltec+mela DW. Galltec+mela DW 10 pages. Sensors for humidity and temperature measurement with calibrated dmodul
Digit
Technical Data
7 8
Measured value and output range 1
9 10
Measured value and ouput range 2
hx-values (as shown on the right)
only available for
industrial versions DKK and DWK
11
Supply voltage
12 13 Measuring head / Filter / Diameter
14
Sensor tube
15 16
Priority devices available with USB interface:
1)
Product no.
DWK 2 00 F1 37 F 08 U 01
DWK 2 00 F1 37 F 08 U D1
DWK 2 00 F1 37 F 05 U 01
DWK 2 00 F1 37 F 05 U D1
DWK 3 00 F1 37 A 08 U 01
DWK 3 00 F1 37 A 08 U D1
DWK 3 00 F1 37 A 05 U 01
DWK 3 00 F1 37 A 05 U D1
Galltec+Mela
D Series_DW
page 4 of 10
Options
Dew point -20...70°C Td
Enthalpy 0...80 kJ/kg
Mixing ratio 0...100 g/ kg dry air
Absolute humidity 0...100 g/m³
Absolute humidity 0...20 g/m³
Wet bulb temperature -10...50°C
No signal
6...30 V DC or 6...26 V AC / Sensors w. 0...1 V output signal
15...30 V DC or 13...26 V AC / Sensors w. 0...10 V output signal
10...30 V DC with galvanic isolation from the power supply /
sensors w. 4...20mA output signal
ZE08: protective cage, plastic, w. membrane, Ø 12 mm
ZE05: sintered PTFE filter, IP65, Ø 12 mm
Standard
USB interface
Version for wall mounting without display 50 mm sensor tube
Version for wall mounting with display
Output
Output range
signal
1
2x 0 ... 10 V 0 ... 100 % rh -30° ... +70°C Membrane filter without display
2x 0 ... 10 V 0 ... 100 % rh -30° ... +70°C Membrane filter with display
2x 0 ... 10 V 0 ... 100 % rh -30° ... +70°C PTFE filter without display
2x 0 ... 10 V 0 ... 100 % rh -30° ... +70°C PTFE filter with display
2x 4 ... 20 mA 0 ... 100 % rh -30° ... +70°C Membrane filter without display
2x 4 ... 20 mA 0 ... 100 % rh -30° ... +70°C Membrane filter with display
2x 4 ... 20 mA 0 ... 100 % rh -30° ... +70°C PTFE filter without display
2x 4 ... 20 mA 0 ... 100 % rh -30° ... +70°C PTFE filter with display
50 mm sensor tube
Filter
2
options
Order code
D2
H1
X3
A3
A1
W1
00
6
F
A
08
05
0
1)
U
01
D1