HighTek HK-880 Manuel de l'utilisateur - Page 9
Parcourez en ligne ou téléchargez le pdf Manuel de l'utilisateur pour {nom_de_la_catégorie} HighTek HK-880. HighTek HK-880 19 pages. Serial device server
www.szhightek.com
Auto is the default mode of Ethernet, user can set to 100M full/half and 10M full/half
If user need to use the HK-880 to access internet domain name, fill the main and secondary IP into the
DNS server 1 and DNS server 2 are necessary, so that can use the domain name server to explain the IP which domain
name you want to access.
Serial interface setup
Serial interface include :
Serial interface style:232/485/422
Baudrate: 110-460800bps
numeric bit data: 5~9
Stop position: 1、1.5、2
Parity check: None、Odd、Even
Flow control: None、CTS/RTS、DSR/DTR、Xon/Xoff
Inactivity Time: 5~5000 MSEL
Inactivity Time is exceed the value when HK-880 serial interface received the data, it can enclose the
data , then transmit. The system default value is 10 ms, you can set the time under 10 ms if you want
to increase the transmission, this need to according the actual status to set up.
Packing Length: 1~1024 byte
HK-880 will transmit the data packet immediately when the received data reach to value you set, the system default
value is 1024 byte.
Serial interface setup as the picture:
8
Shenzhen FangXingLiuTong Industrial Co.,Ltd