CS1000 Long Range Door Sensor – User Guide
Statistics are stored in non-volatile memory and will persist through a battery change or dead
battery. Both the statistic reporting and alarms can be configured remotely by sending downlink
messages.
The sensor has a periodic Heartbeat / Battery-status message that must be sent to maintain
LoRaWAN network connectivity and provide battery status information. The default period for
this message is 60 minutes and may be configured between two (2) minutes minimum and 48
hours maximum
Reset Notifications
After any type of device reboot a Reset Event uplink message (confirmed) will be sent.
Firmware Version
The firmware information can be retrieved via sending a downlink command. See Configuration
and Integration for details.