AGS Mini Merlin Manuel de l'utilisateur - Page 12
Parcourez en ligne ou téléchargez le pdf Manuel de l'utilisateur pour {nom_de_la_catégorie} AGS Mini Merlin. AGS Mini Merlin 16 pages. Ch4 co: dual gas detector methane & carbon monoxide
Également pour AGS Mini Merlin : Manuel d'installation et d'utilisation (16 pages), Installation Fonctionnement et entretien (20 pages)
![AGS Mini Merlin Manuel de l'utilisateur](/uploads/products/server2/199749/199749.jpg)
MINI MERLIN CH4CO
USER GUIDE
Pilot Water Heater and Boiler Limit Breaker.
The device can be used to directly shut the pilot of a water heater using a product from Field
Controls. The BMS terminals may also be used to connect to a home alarm system.
Remote Shut Off.
Your device has a facility for remote devices to be connected.
The [Remote Shut Off] terminal is NC (Normally Closed) and will alarm when energised Open.
Remote devices cut off the gas supply
when activated.
To reset the device after a remote shut off has been activated – press the Touch Button.
Rev: 08 05-19
12