Service Manual
Verify that the accommodation of the trigger shaft is free of dirt and wall light a small fat layer in
his interior.
Mount the air hose in the rear part of the gun using sealing paste in the thread to avoid air
escapes.
Insert the trigger shaft in to the spring and insert it inside the handle taking special care not to
damage the o-rings. You will note a certain resistance caused by the interference of the seals
with the housing wall.
Screw down the trigger valve nut until it does ceiling in the fund.
Fit the trigger with the pin and hold it with the retention ring.
Place the trigger stop bolt. It must be tight up to eliminating the roominess of the trigger shaft
(without to displace the shaft).
Fix the product input blocks to the gun block with the corresponding bolts. Tighten alternately to
avoid possible leaks.
The gun is now ready for service.
15/20
1.5 Issue
Ref. NR-00008-ENG
http://www.gamapur.com