ML20700 PWI Series Mortise Lock
9.
Install (optional) Weatherseal Gasket:
For non-fire rated door applications, an optional gasket may be
used as a weatherseal between the escutcheon and the
outside door surface.
Peel off the adhesive backing on the gasket and
install the gasket along the edge of the outside
escutcheon assembly (Fig. 9a).
10.
Install Inside Mounting Plate:
Install face plate using four
#8-32 machine screws.
IMPORTANT: For fire rated doors,
also use two #8 surface
mount screws.
Copyright © 2009 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.
Fig. 9a
Outside Face of Door
Access Gasket
Outside Access Trim
Fig. 9b
14
(4) #8-32
Machine Scews
(2) #8 Surface Mount Screws
Required for Fire Rated Doors
Fig. 10a