Adesys SVL0040-I Manuel - Page 10
Parcourez en ligne ou téléchargez le pdf Manuel pour {nom_de_la_catégorie} Adesys SVL0040-I. Adesys SVL0040-I 14 pages.
Adesys B.V. | Wateringen
5
Output switching by SMS
With the SVL, the output channel can be switched by means of an SMS message. The SMS message should
be structured as follows: #<Command><parameter1><parameter2>#
• Command = O (Output).
• Parameter1 = A (Active) of I (Idle) of P (Puls schakelen, default: 2 seconden active).
• Parameter2 = Ingangsnummer.
Note: The output number is not the same as the relay number. Relay number 1 is output 5.
Example SMS message to relay 1:
• Output 5 active: #OA5#
• Output 5 Idle: #OI5#
• Output 5 with default Pulse: #OP5#
• Output 5 with 8s Pulse: #OP58#
• Output 5 with 20s Pulse: #OP520#
Manual SVL 4G Weblogger
Figure 3 Connectsticker
Page 10