3- Learning Procedure
All the switches must be put in OFF position.
-
Leds Status in starting product
o
o
If a learning process has already been done on the product, the red led is ON and the green one
blinks quickly on the receiver.
A new learning process can be done without problem.
-
On the receiver
o
-
On the receiver
o
o
The learning process can be deleted by a short-circuit during 2 seconds between the two
« EFF » test points when turning ON the product.
4- Leds Status
Green Led status
Transmitter
OFF
ON
Green Led status
Receiver
OFF
OFF
OFF
ON
ARF30-Analog-Quick-Start-Guide-10-02-V1-CGN-GB
[Transmitter] Green Led ON
[Receiver] Red Led BLINKING (twice per sec)
Put the switch AP to ON
[Receiver] The red led is blinking (Once per sec)
Put the switch AP to OFF
[Receiver]
The red led is ON
[Receiver]
The green led is ON
Red led status
OFF
BLINK 2x/sec
BLINK 1x/sec
ON
Quick Start Guide A
Comment
Product power off
Product power on
Comment
Product power off
Product not configurer (unpaired)
Product in learning mode (pairing)
Product configured and working