● Regarding the temperatures and charging time of the battery.
The temperatures and charging time will become as shown in Table 2-a (UC18YFSL), Table 2-b (UC18YSL3)
Type of battery
Temperatures at which the
battery can be recharged
Charging voltage
Battery
Charging time,
approx. (At 20°C)
Type of battery
Temperatures at which the
battery can be recharged
Charging voltage
Battery
Charging time,
approx. (At 20°C)
Charging voltage
USB
Charging current
NOTE
The recharging time may vary according to the ambient
temperature and power source voltage.
CAUTION
When the battery charger has been continuously used,
the battery charger will be heated, thus constituting
the cause of the failures. Once the charging has been
completed, give 15 minutes rest until the next charging.
4. Disconnect the charger's power cord from the
receptacle.
5. Hold the charger fi rmly and pull out the battery.
NOTE
Be sure to pull out the battery from the charger after use,
and then keep it.
CAUTION
○ If the battery is charged while it is heated because it has
been left for a long time in a location subject to direct
sunlight or because the battery has just been used, the
pilot lamp of UC18YFSL charger lights for 1 second,
does not light for 0.5 seconds (off for 0.5 seconds), or
the charge indicator lamp of UC18YSL3 charger lights
for 0.3 seconds, does not light for 0.3 seconds (off for 0.3
seconds). In such a case, fi rst let the battery cool, then
start charging.
Charger
V
14.4
BSL14xx series
(4 cells)
BSL1415S : 20
BSL1415 : 22
BSL1415X : 22
min.
BSL1420 : 30
BSL1425 : 35
BSL1430C : 45
Charger
V
14.4
BSL14xx series
(4 cells)
BSL1415S : 15
BSL1415 : 15
BSL1415X : 15
min.
BSL1420 : 20
BSL1425 : 25
BSL1430C : 30
V
A
Table 2-a
UC18YFSL
Li-ion
0°C – 50°C
(8 cells)
(5 cells)
BSL1815S : 20
BSL1430 : 45
BSL1815 : 22
BSL1440 : 60
BSL1815X : 22
BSL1450 : 75
BSL1820 : 30
BSL1460 : 90
BSL1825 : 35
BSL1830C : 45
Table 2-b
UC18YSL3
Li-ion
0°C – 50°C
(8 cells)
(5 cells)
BSL1815S : 15
BSL1430 : 20
BSL1815 : 15
BSL1440 : 26
BSL1815X : 15
BSL1450 : 32
BSL1820 : 20
BSL1460 : 38
BSL1825 : 25
BSL1830C : 30
5
2
○ When the pilot lamp or charge indicator lamp fl ickers in
red (at 0.2-seconds intervals), check for and take out
any foreign objects in the charger's battery connector. If
there are no foreign objects, it is probable that the battery
or charger is malfunctioning. Take it to your authorized
Service Center.
○ Since the built-in micro computer takes about 3
seconds to confi rm that the battery being charged with
charger is taken out, wait for a minimum of 3 seconds
before reinserting it to continue charging. If the battery
is reinserted within 3 seconds, the battery may not be
properly charged.
9
18
BSL18xx series
(10 cells)
BSL1830 : 45
BSL1840 : 60
BSL1850 : 75
BSL1860 : 90
18
BSL18xx series
(10 cells)
BSL1830 : 20
BSL1840 : 26
BSL1850 : 32
BSL1860 : 38
Multi volt
series
(10 cells)
BSL36A18 : 75
BSL36B18 : 120
Multi volt
series
(10 cells)
BSL36A18 : 32
BSL36B18 : 52