TOOLS REQUIRED
Adjustable Wrench
Plumbers' Putty or Caulking
ROUGH-IN DIMENSIONS
2-5/16" D.
LEVER HANDLE OPTIONS
2-5/16" D.
Phillips Screwdriver
Regular Screwdriver
1/2" NPT VALVE
REF. DIM.
2-1/8" MIN.
2-7/8" MAX.
3/2" NPT VALVE
REF. DIM.
2-3/8" MIN.
3-1/8" MAX.
1
INSTALL CROSS HANDLE
Apply sealant to groove on back side of ESCUTCHEON (4). Slide ESCUTCHEON (4) onto BARREL SLEEVE (1).
Install BARREL SLEEVE (1) over VALVE STEM (2) and thread onto VALVE (3) until it seats tight against
the internal stop.
Slide ESCUTCHEON (4) flush against finished wall to cover wall opening.
With VALVE in off position align CROSS HANDLE (5) as shown or as desired. Install CROSS HANDLE (5) onto
VALVE STEM (2) and tighten HANDLE SCREW (6). Thread INDEX (7) into CROSS HANDLE (5).
2
INSTALL LEVER HANDLE
Apply sealant to groove on back side of ESCUTCHEON (4). Slide ESCUTCHEON (4) onto BARREL SLEEVE (1).
Install BARREL SLEEVE (1) over VALVE STEM (2) and thread onto VALVE (3) until it seats tight against
the internal stop.
Slide ESCUTCHEON (4) flush against finished wall to cover wall opening.
For Lever Handles: Install FRICTION WASHER (5) onto base of LEVER HANDLE (6). With VALVE in off position
align LEVER HANDLE (6) as shown or as desired. Install LEVER HANDLE (6) onto VALVE STEM (2) and tighten
SET SCREW (7) with HEX WRENCH (8) supplied.
LEVER HANDLE OPTIONS
1 0 9 5 9 0
Turn off hot and cold water
CAUTION
supplies before beginning.
2
4
1
5
6
7
SEALANT
Turn off hot and cold water
CAUTION
supplies before beginning.
1
5
6
7
8
3
2
4
3
SEALANT
1 0 9 5 9 0