Installation Requirements

This mixer tap must be installed
in compliance with current water
regulations. If you have any
doubts about the water regulation
requirements contact your local
water services provider or use the
services of a professional plumber.
This mixer tap is suitable for use with
the following water supply systems:
• Gravity Fed Hot and Cold
(pressure balanced)
• Gravity Fed Hot and Mains
Cold (differential pressure - see
Specification section on page 6)
• Instantaneous water heater
(combination boiler)
• Unvented System
• Pumped System
Gravity Fed Hot and Cold
cold mains supply
Need help? Give us a call on 0330 026 6273 and speak to one of our trained advisors.
6
there must be a minimum head
(vertical distance) from the underside
of the cold water storage tank to the
outlet of at least 2 metres .
Note: Pumped system (with Essex
flange) If you install this mixer valve
to a pumped gravity fed system
where the minimum head (vertical
distance) from the underside of the
cold water storage tank to the top
of the hot water cylinder is less than
1 metre we recommend an Essex
flange is used as shown.
Flushing Pipework
pipework must be flushed to clear
debris before connecting the
mixer tap. Debris will reduce the
performance and life of the mixer.
Gravity Fed Hot and Mains Cold
2m
min.
Important: If you install this mixer
tap with a gravity fed system,
Important: Before connecting
the mixer tap the supply
cold mains supply
2m min.