Decagon Devices EM50G Manuel de démarrage rapide - Page 2
Parcourez en ligne ou téléchargez le pdf Manuel de démarrage rapide pour {nom_de_la_catégorie} Decagon Devices EM50G. Decagon Devices EM50G 2 pages. Using with a user supplied sim
Également pour Decagon Devices EM50G : Manuel de démarrage rapide (2 pages), Manuel (4 pages), Démarrage rapide (2 pages)
8.
Click "OK" after making configuration changes. Click "Apply" to
save communication settings in your Em50G. Your current settings will show
up in the communications option field.
9.
Communication Test: Check the quality of the cellular
communication by clicking the "Test" button. The test takes approximately
30-60 seconds while the Em50G establishes a connection with the cellular
network and the Decagon Data Service. Once the testing is finished, the
"Connection Quality" field reports connection quality. After the initial test,
you can click the test button again to update the status of the cellular signal
strength and connection to the Data Service. Click the "Close" button once
you've evaluated the cellular coverage at your location.
Installing The Em50G
1.
Perform a Communication Test to confirm that there is good cellular
coverage at your site. If cellular coverage is low, try moving a few meters
away and trying the Communication Test again.
2.
Attach the Em50G in an upright position to a firm post or PVC
pipe, using the five zip ties or similar fasteners.
Test Buttons
The Em50G logger has a TEST button and two indicator lights above the
batteries for basic functionality testing. When you press the TEST button,
the logger performs several checks on internal systems and attempts a
communication session over the cellular network. The logger uses the status
lights during the test as follows:
•
Both the "OK" (green) and "ERROR" (red) lights blink slowly
while the Em50G is performing the tests. Please be patient. It can take as
much as 60 seconds or more to finish the cellular communication tests.
•
The "OK" (green) light pulses when the Em50G is actively sending
data over the cellular network.
•
A solid "OK" (green) light indicates the internal tests passed and
there was successful communication over the cellular network to the
Decagon Data Service. The Em50G leaves the light on for approximately
20 seconds.
•
A solid "ERROR" (red) light indicates an error in the logger or
in communicating to the Decagon Data Service. Please use the
Communication Test feature in ECH2O Utility to find the specific error.
Downloading Data
Downloading Data For The First Time
The Em50G sends all of your data to the Decagon Data Service, where
the data are stored. You will need both DataTrac and the Em50G
Downloader software to download data from the Data Service. Please
download the most up to date versions of both software packages from
the Decagon website (www.decagon.com) BEFORE trying to
download data from our server.
1.
Start the Em50G Downloader and set the user configuration
information if this is your first time using the software package.
2.
Click the "Add" button to add a new subscription (a
subscription is required for each Em50G).
3.
You will be asked for the Device ID and password for each
Em50G data logger that you subscribe to. Enter the Device ID and
password exactly as they appear on your brightly colored card that
came inside of your data logger. Both the ID and password are case
sensitive.
4.
Pick the appropriate server where your data are stored. Unless
Decagon has told you otherwise, your data are being stored on the
"ech2odata.com" server.
5.
Pick the amount of data you want to include in the first
download. If this is the first time you are downloading data from this
logger, you should choose the "All Data Points" option. If you are only
interested in downloading data uploaded over the last day or last week,
choose "Last Day" or "Last Week" respectively.
6.
Click "OK". The Em50G Downloader will communicate with
the Decagon Data Service to verify the information you've entered.