Operation
Temperature Adjustment
Turn the knob
anti-clockwise to the
maximum
flow/temperature position.
Remove the knob and
using a
flat bladed screwdriver
turn the adjusting screw.
Maintenance - Cartridge Cleaning
1
2
Remove cap
and loosen the
handle grub
screw.
5
4
Remove all visible
seals and soak the
metal parts in a
suitable solution
until fully descaled.
General Cleaning
Bristan products are made from premium
materials, with hand polishing and
electroplated finishes.
Your taps or shower should be regularly
cleaned with warm water, a mild pH-neutral
liquid soap, and polished with a soft cloth.
Any residues from soap, toothpaste,
Increase
shampoos and shower gels can cause
blemishes if not rinsed off straight after use.
temperature
Decrease
Household bleaches and cleaners contain
temperature
harsh chemicals and may damage the
surface finish. Avoid using abrasive cloths,
scouring pads, scrub sponges, steel wool
or anything similar.
Some surfaces such as nickel and pewter
may be affected by the dye found in some
cloths, so it is also important to avoid
hanging cloths on spouts.
3
Remove the
cartridge, piston
& thermostat.
Remove the
handle.
6
Replace the seal,
Tighten grub
spring, piston,
screw and replace
thermostat and
cartridge.
Troubleshooting
Symptom
Cause
No flow or
Partially closed isolation valve.
low flow
Instantaneous water heater cycles on
rate
and off as flow rate or pressure is too
low.
Head of water is below the
minimum distance required.
Hot or cold water being drawn off
elsewhere causing pressure changes or
instantaneous boiler temperature
changes.
Airlock or partial blockage in the supply
pipework.
Water
This is normal for a short time after using
dripping
the taps.
from taps
If water continues to drip,
possibly due to the ceramic disc valves
Taps do not
Closed isolation valve.
turn on
Mains water supply turned off.
Notes
Please use this space for any notes you or your installer may have regarding the
cap.
At Bristan, we want to make things as easy as possible for our customers.
That's why we offer solid guarantees on all our products, effective from the date of purchase,
to give you peace of mind.
To start your free guarantee simply scan the QR code and register your product.
Alternatively visit www.bristan.com/register to register your product via a computer.
For full guarantee terms and conditions visit www.bristan.com/guarantees.
Remedy
Open isolation valve.
Increase water flow rate or pressure through system.
Refer to specification for minimum distance required.
Do not use other water outlets when using the taps.
Flush through pipework to ensure removal of debris
and any airlocks.
This is caused by residual water tension, the build up
of water in the tap body.
Remove valves and clean, refer to 'Maintenance'
section before starting any maintenance.
Open isolation valve.
Turn on mains water supply.
installation/plumbing of this product.