Bristan NIVA NVA BSM C Instructions d'installation et manuel de l'utilisateur
Parcourez en ligne ou téléchargez le pdf Instructions d'installation et manuel de l'utilisateur pour {nom_de_la_catégorie} Bristan NIVA NVA BSM C. Bristan NIVA NVA BSM C 2 pages.
Specifications
Inlet Water Temperature
60°C
Maximum: 60°C
Maximum Static Pressure: 10.0 bar
Tools You'll Need
Hexagonal Key
Crosshead
Screwdriver
Prior to Installation
All products manufactured and supplied by Bristan are safe provided
they are installed, used correctly and receive regular maintenance in
accordance with these instructions.
This product has been tested to the Water Regulations Advisory
Scheme (WRAS) and satisfies the requirements of the Water Supply
(Water Fittings) Regulations 1999 and current bylaws. For full
Installation Requirements & Notes (IRN) please visit
wras.co.uk/directory.
We recommend isolation valves to be fitted to the inlet water
supplies to ensure ease of future maintenance.
Before installing these taps the water supply must be thoroughly
flushed in order to remove any swarf, solder etc.
This product must not be modified in any way as this will
invalidate the guarantee.
Full access must be made available for future
maintenance/servicing purposes.
If in doubt, contact a registered plumber or your Local Water
Authority or the Secretary of the Institute of Plumbing,
address as follows:-
The Institute of Plumbing,
64 Station Lane,
Hornchurch,
Essex,
RM12 6NB, Tel: 01708 472791
Installation Instructions
& User Guide
Please leave these instructions
with the end user
Product code: NVA BSM C (D1)
Dynamic Water Pressure
Inlet Connections
Min: 0.2 bar
Max: 5.0 bar
3.0
2.0
3.0
2.0
4.0
1.0
1.0
4.0
0.2
5.0
0.2
5.0
Pressure
Pressure
BAR
BAR
Adjustable
Pipe Cutter
Drill
Pencil
Spanner
Pack Contents
x1
x1
x1
x2
x2
Spare Parts
To replace any spare parts
for your tap, why not
scan the QR Code or
visit www.bristan.com
and search for your product.
Installation
1
Feed the tap body through the tap holes,
ensuring the plinths are in place.
3
Connect the hot and cold
3/4" BSP
water supplies to the
threaded tails.
x2
Hose Connection
x2
1
Secure nut end of hose
onto the threaded
outlet connection,
ensuring the washer
is in place before
securing
x1
2
Secure the taps to the bath by using
the washer and metal backnut below
the bath.
4
2
Secure the cone end of
hose onto the threaded inlet
connection of the handset,
ensuring the washer is in
place, before tightening