Step-by-step
Removal of black iron oxide and non-
magnetic material for combination/sealed
systems
Complete all relevant preliminary
1
electrical safety checks to boiler and
pipework to confirm safe isolation
and earth path.
Isolate central heating system and
2
drain.
If a MagnaClean filter is installed,
3
remove the filter. Do not remove the
valves.
Attach the MagnaCleanse hoses
between the RapidFlush Filter and the
MagnaCleanse HTV connector.
Attach MagnaCleanse HTV connector
to the isolation valve on the pipework,
using the appropriate adaptor.
Ensure drain valve is in lower hose.
N.B. The flow through MagnaCleanse
RapidFlush filter should enter the
bottom right and exit top left.
Turn OFF isolation valves on the
4
RapidFlush filter. Loosen and remove
the lid assembly from one of the
RapidFlush filter canisters.
Check jubilee clips are secure
before and during operation.