100mm Wallvent Fixing Internal Grille
1.
Unclip the louvre panel from the grille backplate by
using a flat head screwdriver in the gap shown in Fig.3.
2.
The preformed holes for fixing the internal grille to the
internal wall will be located at each corner of the
backplate – refer to Fig.4.
3.
To fix the internal grille, apply a bead of sealant around
the spigot.
4.
Insert the internal grille backplate into the duct.
5.
Before the sealant sets, ensure the grille is flush and
level before screw fixing.
80001286 – Issue 1 01/23