Centrometal El-Cm Compact 6 Manuel technique - Page 5

Parcourez en ligne ou téléchargez le pdf Manuel technique pour {nom_de_la_catégorie} Centrometal El-Cm Compact 6. Centrometal El-Cm Compact 6 16 pages. Electric boiler and additional equipment

Centrometal El-Cm Compact 6 Manuel technique

Boiler parts

OUTLET
The outlet tube (1") is marked by the blue coloured sticker and is placed on the upper left side of the
electric boiler. It is inserted through the whole length of the electric boiler till its deepest point in order
to spread the cooled water inside the electric boilers body and over the electric heater/heaters.
SENSOR PROBE
On the upper side of the electric boiler is placed sensor probe of the boiler regulation.
SAFETY THERMOSTAT
Overlie security thermostat is situated on the upper side of the boiler, by the pressure switch, when it
is activated it turn off the boiler power supply.
ELECTRIC HEATERS
Electric heaters are situated on the lower part of the electric boiler. Their capacity depends on the
total maximal capacity of the electric boiler.
THERMAL INSULATION
The electric boiler is insulated with mineral wool insulation coating, thickness is 30 mm and is
placed on the aluminium-foil, which prevents losses of heat through convection and radiation.
FILLING - DRAINING / SAFETY VALVE
On the lower part of the electric boiler there is a sealed filling-draining cock for the boiler and the
whole system, as well as certified security valve with an opening pressure of 2,5 bar.
CIRCULATION PUMP / EXPANSION VESSEL
The electric boiler is also supplied by a circulation pump situated on the upper side of the boiler
connected to the inlet, as well as by an expansion vessel situated on the outlet.
PRESSURE SWITCH
In case of pressure loss, the pressure switch turns off the boiler regulation to prevent the operating
of the electric boiler without water, but the power supply to the boiler is not disconnect.
MICRO SWITCH
In case the cover of the electric boiler has been opened, micro switch turn off the operation of the
boiler regulation, but the power supply to the boiler is not disconnect.
BOILER REGULATION
The boiler regulation steers the electric heaters and pump operation and is situated on the console
of the boiler regulation on the right side of the electric boiler.
Technical manual El-Cm Compact
5