Fan Range
Installation and Operating Guide
Aria 100B
Aria 100T
Aria 100H
Aria 100MST - 90000690
Electrical installation
Aria 100B, 100HT, 100MST
Wiring for fans with no external switching
Aria 100T, 100HT, 100MST
Wiring for fans with external switching
Page 5 of 16
Fan dimensions
Aria 100
Fan overview
1
5
- 90000687
- 90000688
- 90000689
1-cover, 2-casing, 3-motor
4-impeller, 5-control.
Page 2 of 16
Mechanical installation
Aria fans can be wall mounted.
For mounting the fan, a ø100mm is required for the
spigot, as well as at least two holes for the mounting
screws. When mounting the fan, remove the front
cover and place the fan into the pre drilled hole. Make
sure that the spigot fits into any pre-installed ducting.
Wire the fan appropriately according to page 5,
ensuring that the cables from the fan are routed
through the provided cable hole.
Use at least two mounting screws to secure the fan to
the ceiling or wall ensuring not to over tighten and
replace the front cover with the retention screw.
Ensure free running of the fan impeller and that
flexible duct connections are not over tightened to the
fan outlet spigot.
Airflow recommends that rigid ducting is used instead
of flexible ducting, this will ensure maximum
performance
Page 6 of 16
Range overview
Aria fans are designed for ventilation of domestic
premises i.e. bathrooms, toilets and shower rooms.
They are recommended for 'through the wall'
instilation.
The Aria 100B model may be used as a simple
extract fan operated by a remote switch.
The Aria 100T model includes an adjustable timer
function 2 to 30 minutes.
The Aria 100HT model includes an adjustable timer
function 2 to 30 minutes and an adjustable humidity
function 60 to 90% RH.
The Aria 100MST models includes adjustable timer
function 2 to 30 minutes and motion sensing.
2
3
4
Max flow,
Fan Size
100mm
Fan assembly - Timer and Humidity /Timer
Electronic
Front cover
Electrical installation
The Aria fan range is IPX4 rated and is suitable for
mounting in Zone 2 in bathrooms, toilets, kitchens,
utility rooms and inside shower cubicles when installed
with a 30mA RCD. In addition AFDD protection is also
required.
The fan requires a 220 - 240V 50Hz single phase
supply. Class II equipment. BS EN 60417. An external
3A fuse is required for each fan unit. Cable sizes
(max): Fixed flat wiring 2 core 1mm
All electrical installation work to be carried out by a
competent person in compliance with the relevant
Building Regulations/Standards as well as the current
edition of BS7671 (IET Wiring Regulations).
Important notes
The Aria range also complies with the requirements of
the EU norms and directives. Do not place the
ventilator near direct heat sources, e.g. radiant
heaters, or where temperatures can exceed 40°C
(104°F). Precautions must be taken to avoid back flow
of gases in rooms with open flue fuel burning
appliances.
Max
Noise
Nominal
pres-
level
3
m
/h
power, W
sure, Pa
dB(A)
66.5
31.8
6
26
Page 3 of 16
Fan adjustment - Timer
The fan with timer function switches on when the
voltage is supplied to the Ls terminal via an external
switch.
Fan body
After the voltage to the Ls terminal is disconnected the
fan continues to run for the set overrun period between
assembly
2 and 30 minutes. The overrun period is adjusted by
Control
turning the potentiometer (T) clockwise to increase and
T & HT
anti-clockwise to decrease.
Page 7 of 16
2
2
, 3 core 1/1.5mm
Page 4 of 16
T
Page 8 of 16