TECHNICAL INFORMATION
Display:
LCD
Working Voltage:
230V~50Hz
Operating Temp:
-5°C to +40°C
Operation:
Relay Control
Max Load:
Resistive -
13A
Inductive -
6A at 0.4 power factor inductive loading
Isolation:
Double Pole Isolation Switch
Conforms to:
BS 1363-4:1995+A4:2012,
BS EN 60730-1:2011,
BS EN 60730-2-7:2010.
Working Environment: Indoor use only
2
Pollution Degree:
GUARANTEE
Your KingShield Fused Spur Switch with Countdown timer
is guaranteed for 12 months from the date of purchase.
This does not affect your statutory rights.
PLEASE KEEP THESE INSTRUCTIONS
SAFE FOR FUTURE REFERENCE
WEST ROAD . HARLOW
ESSEX . CM20 2BG . UK
i n f o @ g r e e n b r o o k . c o . u k
W W W. G R E E N B R O O K . C O . U K
Installation /Operating Instruction
for Fused Spur Switch with Countdown Timer
- Model: T206-C
Please read the instructions fully before attempting installation.
IMPORTANT
This unit should be installed by a competent person
in accordance with the current IET Wiring Regulations.
If in doubt consult a qualified electrician
• Spur switch must not be mounted on a flammable surface.
• Ensure that the Spur switch does not come into contact with any combustible
materials such as towels or bedding.
• Ensure at least a 300mm air space is allowed around the Spur switch.
• A 12mm pattress is provided if extra spacing is required.
• Twin Earth terminal provided.
Note: Where earthing termination is required this must be connected to a earth
terminal as provided in a metal back box.
OPERATING INSTRUCTIONS
'ON' Indicator
Fuse
Holder
Double Pole
Isolation Switch
Dia.1
Note: When first connected to the power this device will automatically
resort to the default setting
• When power is switched off the timer will automatically reset to
the last saved programmed setting.
• If no new program has been input, it will re-set to default setting
Default Setting:
- Password: 1234
- Default countdown time: 4 hours
- Default step: 1/4 hour
A full display will show when the device reverts
to default screen (04.00) Dia.2.
TO RESET THE DEVICE TO DEFAULT SETTING
To fully reset this unit, press the recessed 'Reset'
button with an insulated blunt probe, press and
hold simultaneously buttons '-' and 'set' buttons
for 10 seconds to reset the device to default setting
in operation - 'operation' mode.
(Dia.3 - Full display)
.
Set
Reset
Button
Button
'+' and ' '
Button
Start/Pause
Button
Front Cable
Entry
Dia.2
Dia.3