AUTO CLOSE
Ensure controller is in programming mode (SET and L2 are ON).
Press and hold the TEST button. L1 will start flashing. When L1 flashes twice release the TEST
push button.
Press TEST button and wait until the STATUS LED flashes once.
Release TEST button.
AUTO CLOSE TIME is now ON and set to 15 seconds (Factory default).
Remove the SET link from the set jumper and store the link on one of the pins of the jumper, if
you want to exit program mode.
AUTO CLOSE TIME
Ensure that the controller is in programming mode (SET and L2 are ON).
Press and hold TEST button. L1 starts flashing. When L1 flashes three times release the TEST
push button (One flash of STATUS is equal to one second of auto-close time).
Release the TEST button after the STATUS LED has flashed the required number of times.
AUTO CLOSE TIME is now set.
Remove the SET link from the set jumper and store the link on one of the pins of the jumper, if
you want to exit the program mode.
COLLISION SENSITIVITY
Ensure the controller is in programming mode (SET and L2 are ON).
Press and hold the TEST button.
L1 starts flashing; after 7 flashes release TEST button and L2 will go OFF.
Press TEST button and wait for STATUS to flash;
1 flash = High sensitivity (Gate stops easily)(Default setting)
2 flashes = Medium sensitivity (Gate stop with reasonable effort)
3 flashes = Low sensitivity (Gate stops with difficulty)
Release the TEST button after required number of flashes.
L2 will go ON.
COLLISION SENSITIVITY is set; remove the SET link from the set jumper and store the link on
one of the pins of the jumper, if you want to exit program mode.