6. Technical Specifications

It is a 24V DC battery-operated unit with the following limitations:
Operator push force - starting
Operator push force - rated
Gate mass – maximum
Gate length – maximum
Maximum numbers of operations per day
Based on a push force of less than 50% of rated
Depends on speed setting
D10 Turbo maximum operating speed for corresponding gate mass
Gate mass (kg)
240
300
400
500
600
700
800
900
1000

7. Preparation of site

General considerations for the installation

For comprehensive information, please refer to the full installation
manual available for download on www.centsys.com.au
Install the gate operator only if:
 It will not pose a hazard to the public
 There is sufficient clearance to a roadway and/or public
thoroughfares
 The installation will meet all municipal and/or local authority
requirements once completed
 The gate mass, length and application is within the operator
specifications
 The gate is in good working order, meaning:
 That it moves freely
 Does not move on its own if left in any position
 It can be installed to have sufficient clearance between
moving parts when opening and closing to reduce the risk of
personal injury and entrapment
 Pushbuttons or keyswitches, when required, can be positioned
so that the gate is in line of sight of the operator
Make sure the gate mass,
starting - and rated-pull-force
limitations are not exceeded.
Typical anti-lift
arrangements
Guide-rollers must ensure that
the gate is held vertically through
the entire length of the gate
travel. For improved safety fit
additional support posts to
prevent gate from falling over
if guide rollers fail.
Ensure that the gate
cannot be lifted off the
motor pinion with the
anti-lift bracket fitted
Endstops
Endstop
Fit endstops capable of stopping the gate at rated speed.
Make H>h to ensure gate will not jump over endstop as shown
above
Since the D10 Turbo operates at exceptionally high speeds, it is
mandatory to install the following additional safety equipment in order
to ensure the safest possible installation:
 Opening safety beams, which will prevent the gate from moving
should anyone be in the path of the gate while opening
With a brush replacement interval of two years
Operator max. running speed (m/min)
50
42
36
32
29
27
25
24
23
Additional
support post
Guide-rollers
D10
40kgf
30kgf
1000kg
100m
750
Pull scale
GAP<5mm
GAP<5mm
Ø16mm
D10 Turbo
20kgf
15kgf
1000kg
50m
750
GAP<5mm
GAP<5mm
Endstop