3. INSTRUMENT LAYOUT
Jaw Trigger
Data Hold
& Backlight
Switch
Mode Switch
Range Selector
Switch for Volts
and Resistance
COM
Terminal
4. SPECIFICATIONS
Clamp Size
Diode Test
Continuity Check
Low Battery Indication
Overrange Indication
Measurements Rate
Input Impedance
Display
AC Current
AC Voltage Bandwidth
Operating Temperature
Storage Temperature
Relative Humidity
Over Voltage
Battery
Auto Power Off
Dimensions
Weight
5
30mm Opening Approx
Test Current of 0.3mA typical;
Open circuit voltage 1.5V DC
Threshold <100Ω; Test current <1mA
+
" " is displayed
"OL" is displayed
2 per second, nominal
7.8MΩ (VDC and VAC)
4000 count LCD
50/60Hz (AAC)
50/60Hz (VAC)
-10ºC to 50ºC (-14ºF to 122ºF)
-30ºC to 60ºC (-14ºF to 140ºF)
Up to 85%
Category lll 600V
One PP3 "9V" Battery
Approx 30 minutes
229 x 80 x 49mm
303g
Transformer
Jaws
Function
Switch
Frequency,
Duty Cycle
Switch
Display
Volt, Resistance,
Frequency,
Temperature
Terminal